Elatec GmbH
Page 20 of 65
6.2.7 Example
This example shows how to log into sector 0 of a Mifare
®
card, using transport key FFh:
STX
Station ID
Length
Data
BCC
ETX
02
01
04
6C 00 FF 0D
9B
03
6.2.8 Remarks
If an invalid instruction frame is received (e.g. BCC is wrong) or if the requested Station ID does not