5. Register Set
The reader has several system flags customizing its behavior. The flags are stored non-volatile in its
EEPROM. It is recommended to keep all bits labeled RFU at their default state to guarantee further
compatibility.
Please consider that if any register is written, the reader needs a reset so that the changes may take
effect.
5.1 EEPROM Memory Organization
Register
Access
Default value
Description
00h … 04h
RO
XXh
Unique device ID
05h … 09h
RO
00h
Internal use
0Ah
R/W
01h
Station ID
0Bh
R/W
41h
Protocol Configuration Register 1
0Ch
R/W
00h
Baudrate Control Register
0Dh
R/W
20h
RFU, never change this register
0Eh
R/W
7Fh
Operation mode Register 1
0Fh
R/W
0Ah
RFU, never change this register
10h
R/W
00h
Internal use
11h
R/W
00h
Internal use
12h
R/W
00h
Internal use
13h
R/W
00h
Protocol Configuration Register 2
14h
R/W
0Ah
Reset Off Time
15h
R/W
25h
Reset Recovery Time
16h
R/W
00h
Application Family Identifier AFI
17h
R/W
10h
Internal use
18h
R/W
50h
Internal use
19h
R/W
10h
Internal use
1Ah
R/W
20h
Internal use
1Bh
R/W
00h
Protocol Configuration Register 3
1Ch … 1Fh
R/W
00h
Internal use
20h … DFh
R/W
FFh
RFU, never change this register
E0h … EFh
R/W
00h
Installation Identifier
F0h … FDh
R/W
FFh
RFU, never change this register
FEh
R/W
01h
Operation Mode Register 2
FFh
R/W
22h
Beep tone and length (Nano Module Multi ISO only)