DK50 4VR/50
04/2018
- 5 -
NP-DK50 4VR50-11_04-2018
5.
TECHNICAL DATA
DK50 4VR/50
DK50 4VR/50S
Rated voltage /
frequency
V / Hz
3x400/50
3x400/50
Compressor output
at pressure of 6 bar
L.min
-1
250
250
Compressor output at 6 bar with
dryer
MD
L.min
-1
200
200
NDM
180
180
Peak compressor current A
4.7
5.1
Maximum compressor current with dryer
A
4.8
5.2
Motor output
kW
2.2
2.2
Air tank capacity
L
50
50
Working pressure
bar
6.0 – 8.0
6.0 – 8.0
Maximum operating pressure of safety valve bar
12.0
12.0
Noise
L
pfA
[dB]
77
58
Mode of operation
Continuous S1
Continuous S1
Mode of operation with dryer
Continuous S1
Continuous S1
Compressor dimensions W x L x H
mm
580x580x790
750x770x1015
Dimensions
with dryer
W x L x H
MD
mm
580x635x790
NDM
580x635x790
Weight
kg
70
128
Weight
with dryer
MD
kg
81
139
NDM
89
147
Air dryer performance
Atmospheric dew point
MD
°C
-20
Pressure dew point
NDM
-40
Configuration pursuant to STN EN 60 601-1
Type B, class I.
- Air leaving the dryer is filtered using a 5 µm filter at a minimum.
Climatic conditions during storage and transport
Temperature : –25°C to +55°C, 24 h to +70°C
Relative air humidity : 10% to 90 % (no condensation)
Climatic operation conditions
Temperature : +5°C to +40°C
Relative air humidity : 70%
5.1.
FAD efficiency correction for differences in elevation
FAD
correction
table
FAD efficiency refers to conditions at an elevation of 0 mamsl:
Temperature: 20°C
Atmospheric pressure: 101325 Pa
Relative humidity: 0%
Elevation
[
mamsl
]
0
‐
1500
1501
‐
2500
2501
‐
3500
3501
‐
4500
FAD
[l/min]
FAD
x
1
FAD
x
0.8
FAD
x
0.71
FAD
x
0.60
Summary of Contents for DK50 4VR/50
Page 1: ......
Page 10: ...DK50 4VR 50 NP DK50 4VR50 11_04 2018 10 04 2018 Fig 3 Compressor with adsorption dryer NDM...
Page 11: ...DK50 4VR 50 04 2018 11 NP DK50 4VR50 11_04 2018 Fig 4 Cabinet...
Page 27: ...DK50 4VR 50 NP DK50 4VR50 11_04 2018 130 04 2018 NP DK50 4VR50 11_04 2018 112000123 000...