INSTALLATION
03/2022
37
NP-DK50 2V 50, 2x2V 110-AD-A-1_03-2022
Connect the pin for equipotential bonding
6
mm (1) to the electrical circuit using the
defined
method
under
valid
electrical
engineering regulations
The socket for equipotential bonding (2) is an
accessory and is not provided in the basic
package
Fig. 11 :Equipotential bonding
Mount the connector of the grounding conductor on the door and screw on the cabinet.
Power supply connection
Supply voltage
Electric wire type
230V/50 (60) Hz
3Gx1.5x4000
400V/50 (60) Hz
5Gx1.5x4000
12.1. Connecting a compressor not installed in a cabinet
Insert the mains plug into a rated mains socket.
The compressor is ready for operation.
12.2. Connecting a compressor installed in a cabinet
Route the mains plug through the opening in the rear wall of the cabinet for cabinet-mounted
compressors (Fig. 12).
Connect the cabinet electrically to the compressor by inserting the provided power cord with
connector into an outlet. (Fig. 13)
Disconnect the cabinet electrically from the compressor by pulling the connector from the outlet
while the latch is released.
Connect the display at the front door of the cabinet and then secure the cord to the display in
the clamps (1) (Fig. 18, Fig. 21).
Fig. 12: Opening in the rear wall of the cabinet
Summary of Contents for DK50 2V/50/M
Page 1: ...N VOD NA POU ITIE SK USER MANUAL EN BENUTZERHANDBUCH DE...
Page 2: ......
Page 4: ...CONTENTS 5 INHALT 76 OBSAH 146...
Page 18: ...PRODUCT DESCRIPTION NP DK50 2V 50 2x2V 110 AD A 1_03 2022 18 03 2022 B DK50 2x2V 110S M...
Page 89: ...PRODUKTBESCHREIBUNG 03 2022 89 NP DK50 2V 50 2x2V 110 AD A 1_03 2022 B DK50 2x2V 110S M...
Page 158: ...POPIS V ROBKU NP DK50 2V 50 2x2V 110 AD A 1_03 2022 158 03 2022 Obr 4 Skrinka A DK50 2V 50S M...
Page 159: ...POPIS V ROBKU 03 2022 159 NP DK50 2V 50 2x2V 110 AD A 1_03 2022 B DK50 2x2V 110S M...
Page 218: ......
Page 219: ......
Page 220: ...NP DK50 2V 50 2x2V 110 AD A 1_03 2022 112000519 000...