background image

OPERATING INSTRUCTIONS

ekey home

en

Summary of Contents for home CP micro plus

Page 1: ...OPERATING INSTRUCTIONS ekey home en...

Page 2: ...s 6 Introduction to the system 7 System overview 7 Scope of delivery 8 Finger scanner 8 Control panel 12 Technical specifications 13 Installation and commissioning 14 Commissioning devices 14 Performi...

Page 3: ...rmal mode 24 Storing user fingers 25 Opening a door 27 Deleting user fingers 28 Deleting all user fingers 29 Resetting the system to default settings 30 Via the app 30 Via the finger scanner 31 Via th...

Page 4: ...rrors and misprints is excluded Declaration of conformity ekey biometric systems GmbH hereby declares that the product conforms to the relevant European Union regulations Warranty and manufacturer s g...

Page 5: ...BT Bluetooth CP Control panel FAR False acceptance rate The false acceptance rate describes the likelihood of a biometric security system granting access to someone who does not have access authoriza...

Page 6: ...accordance with the mounting instructions and the wiring diagram The installation must be performed in full and by a professional The electrical engineer who installs the equipment must approve the ek...

Page 7: ...ANGER Risk of electrocution All ekey home devices are to be operated with Safety Extra Low Voltage SELV Only use power supplies rated protection class 2 according to VDE 0140 1 Failure to do so will c...

Page 8: ...x 5 Motorized lock 6 Cable transfer 7 Control panel 8 Connecting cable from finger scanner to control panel The system is comprised of a finger scanner and a control panel The biometric access control...

Page 9: ...anner Function of the finger scanner 1 Front phalanx 2 Fingerprint Fig 2 Fingerprint The finger scanner detects the fingerprint by means of a line sensor and subsequently processes it It compares the...

Page 10: ...e area Store fingers by swiping the finger evenly downward over the sensor Sensor System programming by Finger Touch a short rapid touch of the sensor with the finger Table 2 Finger scanner controls 1...

Page 11: ...he neighboring fingers 4th Move your finger evenly downward over the sensor Move the whole hand simultaneously Swipe the front phalanx fully over the sensor in order to achieve optimal results The mov...

Page 12: ...system en 11 Optical signals on the finger scanner The 3 LEDs on the finger scanner signal the operating status and function of the overall system 1 Status LED 2 Function LEDs Fig 4 Optical signals on...

Page 13: ...Table 3 Control panel Function of the control panel The control panel is the actuator of the system The control panel switches a relay and makes a digital input available Control and optical signals o...

Page 14: ...ecifications ekey home finger scanner arte Name Unit Values Supply voltage VDC 12 24 Power rating W 1 Relay Quantity 1 Relay switching voltage VDC 42 Relay switching current A 2 Operating temperature...

Page 15: ...wiring diagram You must commission the devices in order to operate your system The system is operated using the administrator fingers or via the ekey home app The system devices must be installed in...

Page 16: ...device Connect the mains supply and perform the test within 10 minutes If 10 minutes have elapsed the mains supply will have to be reconnected in order to conduct this test Step Action Description Di...

Page 17: ...ion of normal mode and usage of the finger scanner with the app The devices must have been commissioned before you start your system administration See Commissioning devices page 14 The finger scanner...

Page 18: ...evice in order to couple it for the first time Step Action Description Display 1st Start the ekey home app 2nd Follow the instructions on the display Couple the mobile device with the finger scanner u...

Page 19: ...finger has been stored You can re enable Bluetooth by accessing the administrator finger menu See Configuration of normal mode and usage of the finger scanner with administrator fingers page 23 Coupli...

Page 20: ...er images are deleted When you reset the coupling any relay names and user images that have been stored will be deleted User names and rights will remain stored on the finger scanner Step Instruction...

Page 21: ...ing code in the corresponding field 5th Confirm by selecting Change The user coupling code was stored Resetting the app security code If you have forgotten the app security code you can use the app to...

Page 22: ...the lost mobile device Step Instruction 1st Start the ekey home app on the second mobile device 2nd Couple the second mobile device with the finger scanner 3rd Select ADMINISTRATION 4th Select CHANGE...

Page 23: ...the finger scanner The system is in normal mode Step Action Description Display 1st Swipe a stored finger over the sensor The finger scanner lights up green The finger scanner lights up red The finge...

Page 24: ...nger scanner with administrator fingers The devices must have been commissioned before you start your system administration See Commissioning devices page 14 The finger scanner is ready to store the a...

Page 25: ...ministrator finger 1 over the sensor to store it See Correct operation of the finger scanner page 10 Repeat this step at least twice Between each individual finger swipe the finger scanner lights up o...

Page 26: ...ingers are deleted Storing user fingers The system enables a maximum of 99 user fingers to be stored A user finger is any finger which is used for triggering an action on the control panel e g opening...

Page 27: ...first finger has been swiped once over the sensor no more than 10 s may pass between each subsequent swipe Otherwise the finger storing process will be aborted The central LED lights up green The fin...

Page 28: ...e Using the finger scanner The system is in normal mode Step Action Description Display 1st Swipe a stored finger over the sensor The finger scanner lights up green The finger scanner lights up red Th...

Page 29: ...y on the left and right 2nd Swipe any administrator finger over the sensor The finger scanner flashes green The finger scanner lights up red The administrator finger was not recognized Repeat step 1 3...

Page 30: ...es green The finger scanner lights up red The administrator finger was not recognized Repeat step 1 3rd Wait for 5 s The left and right LEDs alternate between flashing red green 4th Carry out a Finger...

Page 31: ...ner settings are reset to their defaults All user and administrator fingers will be irrecoverably deleted The coupling code is reset to the default setting of 9999 the relay switching time to 3 second...

Page 32: ...canner flashes green The finger scanner lights up red 3rd The administrator finger was not recognized Repeat step 1 4th Wait for 5 s The left and right LEDs alternate between flashing red green 5th Ca...

Page 33: ...ing of 9999 Step Action Description Display 1st Press and hold the button with the unlocking spring for at least 4 s The finger scanner flashes blue 2nd No action required The status LED of the ekey h...

Page 34: ...gital input and keep them in this state 3rd Connect the ekey home CP micro plus to the mains supply 4th Keep the request to exit button held down or keep the pins for the digital input short circuited...

Page 35: ...GmbH ensure that it is correctly packaged Improper packaging can lead to the warranty being voided Finger scanner Display Meaning Remedy The finger scanner lights up red The finger was not recognized...

Page 36: ...wels tissues kitchen sponges damp dish towels and kitchen roll are not suitable Use clean water without adding detergent Disposal Pursuant to Directive 2002 96 EC of the European Parliament and Counci...

Page 37: ...lzano Tel 39 0471 922 712 italia ekey net Germany ekey biometric systems Deutschland GmbH Industriestra e 10 D 61118 Bad Vilbel Tel 49 6187 906 96 0 o ce ekey net Eastern Adriatic region ekey biometri...

Reviews: