Resetting the system to default settings
en
│
33
Via the digital input
The process of resetting to the default settings is initiated via the digital input. The
finger scanner settings are reset to their defaults. All user and administrator fingers
will be irrecoverably deleted. The coupling code for the app is reset to the default
setting of
9999
.
Step
Instruction
1st
Disconnect the
ekey home CP micro plus
from the mains supply.
2nd
Press and hold the request-to-exit button or short-circuit the pins for
the digital input and keep them in this state.
3rd
Connect the
ekey home CP micro plus
to the mains supply.
4th
Keep the request-to-exit button held down or keep the pins for the
digital input short-circuited for at least 5 s.
5th
Release the request-to-exit button or remove the short-circuit. Within
5 s, press and hold the request-to-exit button or short-circuit the pins
for the digital input for at least 500 ms.
✓
The finger scanner and the control panel have been reset to the default settings.
You can now recommission the system.
See
“
Configuration of normal mode and usage of the finger scanner with the app
”,
page 16.
See
“
Configuration of normal mode and usage of the finger scanner with
administrator fingers
”, page
23.