When a gas appliance is being used it produces heat and humidity in the room where it is installed. 
For this reason the room must be well ventilated, keeping the natural ventilation openings free (fig. 6) 
and switching on the mechanical aeration system (suction hood or electric fan, Figs. 7 and 8).  
If  the  cooker  is  used  for  a  long  time  additional  aeration  may  be  necessary,  for  instance,  opening  a 
window,  or  a  more  effective  aeration  by  increasing  the  power  of  the  mechanical  system  if  there  is 
one. 

 

 

 

 
Gas connection 

Install  in  accordance  with  relevant  gas  standards  and/or  codes  of  practice 
applicable.  
Connect the elbow fitting to the appliance gas manifold connection, and check    that 
seals  between  the  elbow  and  manifold  connection  are  in  place  and  in  good 
condition.  
For Natural gas: connect the natural gas appliance regulator (pictured opposite) with 
integral test point using approved gas thread tape or compound to the elbow fitting.  
For  Universal  LPG:  connect  the  brass  test  point  adaptor  (pictured  opposite)  using 
approved gas thread tape or compound to the elbow fitting.  
Ensure the supply connection point, test point and natural gas regulator adjustment 
screw (for Natural gas installation) are accessible for testing and/or adjustment with 
the hotplate in the installed position.  
Where  a  flexible  hose  assembly  is  used,  ensure  it  is  approved  to  AS/NZS  1869, 
Class B. Any hose assembly used must be restrained from accidental contact with 
the  flue  outlet  of  an  under  bench  oven.  This  hose  assembly  shall  be  suitable  for 
connection to a fixed consumer piping outlet located as follows: 
Hotplates at a point 800 mm to 850 mm above the floor and in the region outside the 
width of the appliance to a distance of 250 mm. 

   

 

 
After connecting to gas, check for leaks using soapy solution, never a naked flame.  
Fit the duplicate data plate (supplied in separate bag) on a surface adjacent to the hotplate, for example, the inside 
of the cupboard door so it is clearly visible for any service technician.  

 

Summary of Contents for HB4801

Page 1: ...INSTRUCTIONS AND HINTS FOR THE USE INSTALLATION AND MAINTENANCE OF GAS FUELLED BUILT IN HOBS 220 240V 1 2W 50Hz Class I ELS A HG SS60 02...

Page 2: ...his information the technical assistant can come with the right spares and guarantee a prompt job You will find original parts and optional accessories at our Technical Assistance Centres and authoris...

Page 3: ...manufacturer declines all responsibility if these instructions are not followed Should you have any doubts ask for an accurate control of the system by qualified personnel Prior to connecting the app...

Page 4: ...ged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 2 DESCRIPTION OF THE APPLIANCE 1 SABAF Semi Rapid gas burner SR 2 SABAF Rapid ga...

Page 5: ...urner control knob HB5802A HB5802A1 HB5802D HB5802D1 HB5801A HB5801A1 HB5801D HB5801D1 Accessory Name Picture for reference only physical unit maybe different Quantity User Manual 1 Installation clip...

Page 6: ...expected flameout On the top of each knob there is a printed diagram showing to which burner or heating element it refers GENERAL NOTES ON SAFETY When the burners or plates are in use do not leave the...

Page 7: ...peat the operation Optimum use of the burners To get the maximum yield with the minimum consumption of gas it is handy to keep the following points in mind Once the burner has been lit adjust the flam...

Page 8: ...ad tape or compound to the elbow fitting For Universal LPG connect the brass test point adaptor pictured opposite using approved gas thread tape or compound to the elbow fitting Ensure the supply conn...

Page 9: ...al environmental care authority for information on location of such facilities SETTING THE GAS PRESSURE Fit a manometer with a 6 mm rubber hose to the test point on the regulator for natural gas Test...

Page 10: ...ot require adjustment Adjustment may be required if the hotplate has been converted from Natural gas to Universal LPG or vice versa GAS CONVERSION INSTRUCTIONS The manufacturers servicing instructions...

Page 11: ...ot working efficiently Make sure the gas cock is open Check the plug is in Check that the knobs are set correctly for cooking and then repeat the operations given in the handbook Check the electrical...

Page 12: ...bstructed Indirect ventilation is also allowed by taking air from rooms adjacent to the one to be ventilated strictly complying with the prescriptions of the standards in force LOCATION AND AERATION G...

Page 13: ...vable to allow possible operations of maintenance see fig 10 The hob has a special seal which prevents liquid from infiltrating into the cabinet Strictly comply with the following instructions in orde...

Page 14: ...flue outlet of an under bench oven The hose should not be subjected to abrasion kinking or permanent deformation and should be able to be inspected along its entire length Unions compatible with the...

Page 15: ...ervice provider in your area MAINTENANCE Maintenance Schedule No regular maintenance is required for the hotplate except cleaning However it is recommended the hotplate be checked and serviced by an a...

Page 16: ...0 52 0 91 3 2 3 6 3 2 3 8 4 SABAF Wok 2 75 Universal LPG 1 00 Natural 0 95 1 70 10 3 11 3 10 5 12 3 HB5801A HB5802A HB5801D HB5802D HB5801A1 HB5802A1 HB5801D1 HB5802D1 BURNERS TEST POINT PRESSURE DIA...

Page 17: ...not aligned properly Remove and re fit burner Burner not lighting when spark ignition working Gas supply off Check gas supply valve on Burner not aligned properly Remove and re fit burner Burner port...