14
hazardous overheating.
•
The appliance must be positioned so the plug is accessible.
When connecting directly to the mains:
-
Install a multipolar switch that can withstand the appliance load, with a minimum opening between the contacts
of 3 mm.
-
Remember that the earth wire must not be cut out by the switch.
-
As an alternative, the electrical connection can also be protected with a high sensitivity RCD.
Before Leaving
Check all connections for gas leaks with soap and water.
DO NOT
use a naked flame for detecting leaks. Ignite all
burners both individually and concurrently to ensure correct operation of gas valves, burners and ignition. Turn gas
taps to low flame position and observe stability of the flame for each burner individually and concurrently. When
satisfied with the hotplate, please instruct the user on the correct method of operation. In case the appliance fails to
operate correctly after all checks have been carried out, refer to the authorised service provider in your area.
MAINTENANCE
Maintenance Schedule
No regular maintenance is required for the hotplate except cleaning.
However, it is recommended the hotplate be
checked and serviced by an authorised service person every 2 years.
Prior to any maintenance work or before changing parts, disconnect the appliance from the gas and
electricity power sources.
REPLACING COMPONENTS
•
To access the terminal board and the power cable, it is necessary to remove the hob from the cabinet by
unscrewing the relative fixing screws (V) (see fig. 12).
•
If the power cable needs changing, call an authorised Assistance Centre as it is necessary the use of
special utensils. The technician will have to connect a cable with a suitable cross section (see the table
on page 13) keeping the earth wire longer than the phase wires. In addition, follow the instructions giving
in the “ELECTRICAL CONNECTION” paragraph.
•
To replace other gas and electrical components, that are lodged inside the hob, it is enough to remove the work
top unscrewing the fixing screws of the burners
•
Replace the seal each time you change a tap in order to guarantee a perfect tightness between body and rail.