Drawing   : - TPC499 
Issue 

: - 1 

Date 

: - 29/01/20 

OPERATION 

 

The operation of the dehumidifier is to remove moisture from the air by having 
it condense on the cold tubes of the evaporator coil. The air then passes over 
the hot condenser coil and returns to the conditioned space slightly warmer 
and dryer than when it entered the dehumidifier unit. 

 

TEST FOR CORRECT OPERATION 

The following procedures should be followed to test the CD30S for correct 
operation.

 

1.   After unpacking, examine all external features to confirm damage free 

shipment. Report all defects and damage at once. 

2.   Check dehumidification process: 

a)

  Place  unit on  a  level  surface.  Connect  a  suitably  sized  hose  to 

the condensate outlet and run the hose to a permanent drain. 

b)

  Start up  unit  by  rotating  the adjustable  humidistat  knob  counter 

clockwise to the minimum setting. Plug in the unit to a grounded 
receptacle  with  a  15  amp  power  source.  Rotate  the  humidistat 
knob clockwise to the maximum setting. 

c)

  Check the compressor is running. 

d)

  Leave the machine running for 15 minutes. 

e)

  Observe the evaporator coils, to confirm frost formation. 

i.  If  the  air  temperature  is  below  70ºF,  an  even  coating  of 

frost  should  cover  the  entire  evaporator  coils,  except  for 
the last one or two coils. 

ii.  If the temperature is above 70ºF, frost and/or droplets of 

condensed water should cover the entire evaporator coil. 

 

If after carrying out all the above checks, the unit does not appear to function 
correctly refer to the section, “Trouble Shooting”, or contact your supplier. 

 

WARNING: 

  Due  to  the  high  pressures  within  the  refrigeration  circuit,  under  no 

circumstances  must  direct  heat  be  applied  to  the  evaporator  coil  in  an 
attempt to remove the build up of ice. 

  No attempt should be made to cut open any part of the refrigeration circuit 

due  to  high  pressures  and  gas  involved.  If  the  unit  is  switched  off  at  the 
mains power  supply  for  any  reason,  the  unit  must  be  allowed  to  stand at 
rest for at least three minutes before restarting. Failure to do so may cause 
the  unit  to  blow  the  fuses  owing  to  the  compressor  due  to  there  being  a 
refrigerant imbalance.

 

 

Humidistat

 

This humidistat operates to control the on/off function of the dehumidifier unit 
as required. 

 

Summary of Contents for CD30S

Page 1: ...Page 1 of 12 Drawing TPC499 Issue 1 Date 29 01 20 CD30S INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Page 2: ...Page 2 of 12 Drawing TPC499 Issue 1 Date 29 01 20 CD30S PACKAGE CONTENTS Item Description Quantity 1142000 Dehumidifier 1 3014338 PVC tube 12mm I D 3 M 3086101 Jubilee clip 1 TPC449 Manual 1...

Page 3: ...point Moisture forms on the evaporator coil and is collected in the condensate tray which is equipped with a permanent drain The cooled air then passes through the hot condenser coil where it is rehe...

Page 4: ...he Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this u...

Page 5: ...d Leave the machine running for 15 minutes e Observe the evaporator coils to confirm frost formation i If the air temperature is below 70 F an even coating of frost should cover the entire evaporator...

Page 6: ...e 25 C the coil may be covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all...

Page 7: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Page 8: ...oss of refrigerant gas 4 Blocked filter dryer 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center 4 Contact the Factory Service Center Little or no defro...

Page 9: ...R Compressor 1 3944958 Refrigeration Coil Set 1 2139528 Fan Motor 1 3035773 Fan Blade 1 3040129 Timer Board 1 1619519 Humidistat 1 3035145 Humidistat Knob 1 3030421 Solenoid Coil 1 3020421 Defrost By...

Page 10: ...oto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R40...

Page 11: ...Page 11 of 12 Drawing TPC499 Issue 1 Date 29 01 20...

Page 12: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...

Reviews: