background image

 

 

 

 

Page 12 of 12 

Drawing   : - TPC499 
Issue 

: - 1 

Date 

: - 29/01/20 

 

UK Head Office 

 

Ebac Industrial Products Ltd 

St Helens Trading Estate 

Bishop Auckland 

County Durham 

DL14 9AD 

 

Tel: +44 (0) 1388 664400 

Fax: +44 (0) 1388 662590 

 

www.eipl.co.uk

 

[email protected]

 

American Sales Office 

 

Ebac Industrial Products Inc 

700 Thimble Shoals Blvd. 

Suite 109, Newport News 

Virginia, 23606-2575 

USA 

 

Tel: +01 757 873 6800 

Fax: +01 757 873 3632 

 

www.ebacusa.com

 

[email protected]

 

 

German Sales Office 

 

Ebac Industrial Products Ltd. 

Gartenfelder Str. 29-37 

Gebäude 35 

D-13599, Berlin 

Germany 

 

Tel: +49 3043 557241 

Fax: +49 3043 557240 

 

www.eip-ltd.de

 

[email protected]

 

 

Summary of Contents for CD30S

Page 1: ...Page 1 of 12 Drawing TPC499 Issue 1 Date 29 01 20 CD30S INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Page 2: ...Page 2 of 12 Drawing TPC499 Issue 1 Date 29 01 20 CD30S PACKAGE CONTENTS Item Description Quantity 1142000 Dehumidifier 1 3014338 PVC tube 12mm I D 3 M 3086101 Jubilee clip 1 TPC449 Manual 1...

Page 3: ...point Moisture forms on the evaporator coil and is collected in the condensate tray which is equipped with a permanent drain The cooled air then passes through the hot condenser coil where it is rehe...

Page 4: ...he Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this u...

Page 5: ...d Leave the machine running for 15 minutes e Observe the evaporator coils to confirm frost formation i If the air temperature is below 70 F an even coating of frost should cover the entire evaporator...

Page 6: ...e 25 C the coil may be covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all...

Page 7: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Page 8: ...oss of refrigerant gas 4 Blocked filter dryer 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center 4 Contact the Factory Service Center Little or no defro...

Page 9: ...R Compressor 1 3944958 Refrigeration Coil Set 1 2139528 Fan Motor 1 3035773 Fan Blade 1 3040129 Timer Board 1 1619519 Humidistat 1 3035145 Humidistat Knob 1 3030421 Solenoid Coil 1 3020421 Defrost By...

Page 10: ...oto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R40...

Page 11: ...Page 11 of 12 Drawing TPC499 Issue 1 Date 29 01 20...

Page 12: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...