EION: interface Bridge 0 no shutdown
Interface 'Bridge 0' is up.
3. Configure IP address and mask:
EION: interface Bridge 0 ip address 192.168.1.1
Device 'Bridge 0' address 192.168.1.1 netmask 255.255.255.0
4. Add any number of Ethernet based interfaces in a bridge group:
EION: interface Wireless 0 bridge-group 0
Interface 'Wireless 0' was added to the bridge group 0.
EION: interface FastEthernet 0 bridge-group 0
Interface 'FastEthernet 0' was added to the bridge group 0.
Important
After adding the wireless interface and the fast Ethernet interface as part of the bridge group,
the bridge interface picks up the IP address and MAC address of the fast Ethernet interface.
Make sure that the IP address assigned to the bridge is the same as the fast Ethernet IP address,
otherwise you will lose control of the device.
You may check a bridge status after configuration:
EION:
show interfaces
Wireless 0 is up, link state is up
Hardware address: 0015.6d54.9d3c VLAN: none
Internet address: 0.0.0.0 mask 0.0.0.0
broadcast: 0.0.0.0, MTU: 1500
Type: ap, SSID: "", Mode: 802.11a (auto)
Speed: 0 Mb/s (auto), Access point: N/A
Channel: , Frequency: MHz, Tx-power:
RTS: off, Distance: 0, WDS: off, FastFrame: off
Burst: off, Compression: off, WMM: off, Beacon: 0, DFS: off
Antenna: auto, ATPC: off
FastEthernet 0 is up, link state is up
Hardware address: 0001.0000.12ec VLAN: none
Internet address: 192.168.0.5 mask 255.255.255.0
broadcast: 192.168.0.255, MTU: 1500
FastEthernet 1 is up, link state is down
Hardware address: 0003.47df.32ab VLAN: none
Internet address: 0.0.0.0 mask 0.0.0.0
broadcast: 0.0.0.0, MTU: 1500
EION: show bridge-groups
bridge name bridge id STP interfaces
Bridge 0 8000.000347df32a8 no FastEthernet 0
4.4.1.2. Wireless interface configuration
If a
Wireless
interface is a member of a bridge group, and it has an AP or station type, the
WDS
flag
should be set to enable transparent relaying of ethernet frames:
65
Configuration
Summary of Contents for LibraPlus 5845
Page 2: ...This page is intentionally left blank...
Page 10: ...6 5 Show CPU load 109 6 6 Show uptime 109 6 7 Show interfaces 110 x LibraPlus User Manual...
Page 24: ...Fig 2 10 Mounting Fig 2 11 Large Pipe Diameter Mounting Configuration 14 Description...
Page 26: ...2 1 7 Specifications 16 Description...
Page 32: ...Fig 2 15 Point to Multipoint Wireless Network 22 Description...
Page 123: ...7 1 3 Troubleshooting Chart 113 Troubleshooting...
Page 140: ...2009 EION Inc...