Corrective Action
Possible Cause
Indication
Check the following configuration settings:
• Station ID–Each unit must have a unique RF
Station ID
• Sector ID-CPE must have the same as the AP
in their sector
• Synch ID-CPE must have the same as the AP
• Center frequency–Units must have the same
center frequency to communicate
• IP address/subnet mask–Incorrectly configured
IP addresses result in units being unable to
communicate. Check that IP addresses are
unique for each unit within a subnet and that the
correct subnet mask is being used.
Configuration problems
No communication
between units
• Check the maximum remote distance configura-
tion setting
Distance
Poor Link Perform-
ance
• Excessive Bit errors and processing errors
Excessive Bit errors and pro-
cessing errors
• Check LOS for obstacles such as trees
• Change alignement of antenna to take advantage
of beneficial multipath signals
• Move antenna to better location or remove
obstacle if possible
Signal absorption
Set units from different systems in the same geo-
graphical area to different center frequencies –
overlapping wavelengths from other systems will
degrade performance
Interference
Output power from one unit can overpower anoth-
er, colocated, radio, even if units operate on differ-
ent channels
Overpowering Colocated Unit
• Change IP filtering to enable SNMP
IP filtering configured incor-
rectly for SNMP
SNMP can’t be ac-
tivated
• Reload the software image using ftp
Incorrectly upgraded software
New configuration
will not take
Contact EION, Inc. for information about how to
re-enter your system. Units will need to be reset
Invalid Passwords
Unable to access
main configuration
menu
Bench test unit
Faulty unit
Unit will not oper-
ate
• Reload unit software
Corrupt unit software
Table 7.1. Troubleshooting Chart
116
Troubleshooting
Summary of Contents for LibraPlus 5845
Page 2: ...This page is intentionally left blank...
Page 10: ...6 5 Show CPU load 109 6 6 Show uptime 109 6 7 Show interfaces 110 x LibraPlus User Manual...
Page 24: ...Fig 2 10 Mounting Fig 2 11 Large Pipe Diameter Mounting Configuration 14 Description...
Page 26: ...2 1 7 Specifications 16 Description...
Page 32: ...Fig 2 15 Point to Multipoint Wireless Network 22 Description...
Page 123: ...7 1 3 Troubleshooting Chart 113 Troubleshooting...
Page 140: ...2009 EION Inc...