Physical, Electrical and Environ-
mental Specifications
AP, LCPE, ER: Outdoor, rugged
Form-Factor
RD, CPE: Outdoor, antenna integrated
AP, LCPE, ER: Die-cast with metal plate cover
Enclosure
RD, CPE: Die-cast with plastic antenna housing
AP, LCPE, ER: 230 (w) x 65 (d) x 230 (h) mm
Dimensions
RD, CPE: 300 (w) x 90 (d) x 300 (h) mm
AP, LCPE, ER: 2.0 kg
Weight
RD, CPE: 2.3 kg
Yes, 2-Axis pole/wall
Mounting Bracket
15 W MAX
Power Consumption
100/240V, 50/60 Hz AC
Input Voltage
-35° C to +80° C
Operating Temperature
0 to 100%, condensing
Relative Humidity
Enclosure: NEMA 4x; Designed to IP66
Certifications
Environmental: RoHS and WEEE
IC: RSS-210, ISS-03, 8367A-5845001
FCC Part 15.247, subpart C, 15.203, 15.207 (2007), 15.109, 15.407
ETSI EN 301 489-1, EN 301 893, EN 301 489-17 (EMC Wideband data and HIPERLAN
EN 50385-2002, EN 55022, EN 61000
Safety: UL 60950 equivalent EN60950 (EU); Modular approvals (electrical)
Integrated, Telcordia GR-1089 compliant (Meets IEC 61000-4-2/ 4-4)
Lightning Protection