GB
- 31 -
while positioning the hexagon key (13) on the
flange bolt (31) with the other hand.
•
Firmly press on the saw shaft lock (5) and
slowly rotate the flange bolt (31) in the clock-
wise direction. The saw shaft lock (5) engages
after no more than one rotation.
•
Now, using a little more force, slacken the
flange screw (31) in the clockwise direction.
•
Turn the flange screw (31) completely out and
remove the external flange (32).
•
Take the blade (7) off the inner flange and pull
down and out.
•
Carefully clean the flange screw (31), outer
flange (32) and inner flange.
•
Fit and fasten the new saw blade (7) in rever-
se order.
•
Push the cover plate (42) back into its starting
position and secure it with the screw (41).
•
Important! The cutting angle of the teeth, in
other words the direction of rotation of the saw
blade (7), must coincide with the direction of
the arrow on the housing.
•
Check to make sure that all safety devices
are properly mounted and in good working
condition before you begin working with the
saw again.
•
Important! Every time that you change the
saw blade, check to see that it spins freely in
the table insert (12) in both perpendicular and
45° angle settings.
•
Important! Changing and aligning the saw bla-
de (7) must be carried out correctly.
6.8 Transport (Fig. 1-3)
•
Retighten the locking screw (14) to secure the
turntable (17) in place.
•
Activate the release lever (3), press the ma-
chine head (4) downwards and secure with
the safety pin (25). The saw is now locked in
its bottom position.
•
Fix the saw’s drag function with the locking
screw for drag guide (24) in rear position.
•
Carry the equipment by the fixed saw table
(18).
•
To set up the equipment again, proceed as
described in section 5.2.
6.9 Operating the laser (Fig. 2)
Switching on:
Move the On/O
ff
switch (37) to the
“I” position to switch on the laser (35). A laser line
is projected onto the material you wish to process,
providing an exact guide for the cut.
Switching o
ff
: Move the On/O
ff
switch (37) to the
“0” position.
Setting the laser:
If necessary, slacken the
screws to adjust the laser. Retighten the screws
after you have made the adjustment. Important!
Never look directly into the laser beam!
Replacing the battery:
Ensure that the laser (35)
is switched o
ff
. Remove the battery compartment
cover (40). Remove the old batteries and replace
with new ones (2 x 1.5 Volt R03, LR 03 Micro,
AAA). Ensure correct polarity when inserting the
new batteries. Close the battery compartment
again.
6.10 Battery disposal
Recycle the packaging in an environmentally re-
sponsible manner. Sort the packaging for proper
recycling. The product may not be disposed of
with normal household refuse. Consumers have a
legal obligation to dispose of the batteries at the
appropriate collection points. Send your old bat-
teries to iSC GmbH, Eschenstrasse 6 in D-94405
Landau, Germany. You can then be sure that they
will be correctly disposed of by the manufacturer.
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.