9. Troubleshooting
Fault
Cause
Remedy
Engine does not
start
- Spark plug fouled
- Air
fi
lter dirty
- No fuel in the tank
- Automatic oil cut-out has not
responded
- Clean or replace the spark plug
- Clean the air
fi
lter.
- Top up fuel.
- Check oil level, top up engine oil
Pump fails to prime
- Intake valve not in the water
- No water in the pump chamber
- Air in the intake line
- Intake cage (intake valve) blocked
- Max. intake head exceeded
- Place the intake valve in the water
- Fill the pump chamber with water
through the
fi
ller neck
- Check the intake line for leaks and
seal it if necessary.
- Clean intake cage
- Check intake head and reduce it if
necessary
Insu
ffi
cient pumping
rate
- Intake head too high
- Intake cage soiled
- Water level falling rapidly and intake
line is out of the water-
- Pump performance reduced by de-
posits
- Check intake head and reduce it if
necessary
- Clean intake cage
- Place the intake line at a deeper
level
- Clean pump
Important.
The pump must not run dry.
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers
accompanying products is permitted only with the express consent of the iSC GmbH.
Subject to technical changes
Anl_GH_PW_18_SPK9.indb 18
Anl_GH_PW_18_SPK9.indb 18
30.01.2019 11:05:03
30.01.2019 11:05:03
Summary of Contents for GH-PW 18
Page 2: ...2 1 2 10 9 4 3 1 2 3 6 11 16 7 8 2 15 21 21 21 14 5 9 13 13 14 12 18 17 17 19 19 20 20 18...
Page 3: ...3 4 5 6 7 A B C D B A 8 9 H L...
Page 4: ...4 10 11 12 13 14 15...
Page 5: ...5 16 1 2 3 4...
Page 73: ...GR 73 7 7 1 7 2 7 2 1 N 7 A 7 B 8 H L H 8 7 2 2 9 10 11 7 2 3 0 6 12 13 7 2 4 14 15...
Page 74: ...GR 74 7 3 1 6 7 4 www isc gmbh info 8...
Page 75: ...GR 75 9 iSC GmbH M...
Page 76: ...GR 76 www isc gmbh info...
Page 77: ...GR 77 1 2 3 4 24 5 www isc gmbh info...
Page 79: ...79...
Page 80: ...EH 01 2019 01...