1: POWER ON/OFF:
Keep the pushbutton pressed
for a least one second, the equipment will switch on
and the display will flash “000” (Standby mode).
If the pushbutton is pressed for at least one second
when the equipment is switched on, the equipment
will turn off again.
2: 12V DC OUTPUT:
Pressing the pushbutton in
Standby mode will switch on the 12V terminal jack at
the back of the equipment. Press the pushbutton
again and the 12 V terminal jack will switch off and
the equipment returns to Standby mode.
3: 2/6/12 AMP SELECT:
One second after pressing
the pushbutton the equipment will start to charge
with 2A, 6A, 12A or will return to Standby mode. The
display will show the selected action.
4: BATTERY VOLTAGE:
After pressing the
pushbutton in Standby mode or during charging, the
equipment will show the current battery voltage.
b) LED indicators
5: AMP
- the LED lights up while the equipment is
charging or the 12V terminal jack at the back of the
equipment is switched on.
6: VOLT
- the LED lights up when the equipment is
in Standby mode or the pushbutton “BATTERY
VOLTAGE“ is activated.
7: FULL
- the LED lights up when the battery is fully
charged.
8: CHARGING
- the LED lights up during the
charging process.
9: FAULT
- the LED indicates a fault.
10: LED next to 12V DC OUTPUT
- the LED lights
up when the 12V terminal jack at the back of the
equipment is ready for operation.
c) Description of the display
11:
The display indicates the status of the equipment
and the battery.
Indicator:
000
Meaning:
Standby mode
Indicator:
CHE
Meaning:
Check the battery
Indicator:
13.8
Meaning:
Battery voltage is indicated during the
charging process or in Standby mode (for example
13.8 V).
Indicator:
05.8
Meaning:
1. Charging current is indicated (for
example 5.8 A); 2. Output current at the 12V terminal
jack is indicated.
Indicator:
F01
Meaning:
Fault indication
1. Battery pole is not connected; 2. Short circuit
Troubleshooting:
1. Connect the battery pole. 2.
Use a different battery (battery defective).
Indicator:
F02
Meaning:
Connections inserted with reverse polarity
Troubleshooting:
Switch off and disconnect the
mains plug, insert correctly
Indicator:
F03
Meaning:
1. Battery suffers from exhaustive
discharge; 2. Battery cell defective; 3. 6V battery is
connected
Troubleshooting:
Switch off and pull the mains
plug, remove the battery (defective).
Indicator:
F04
Meaning:
1. Battery suffers from cell short circuit;
2. Unsuitable charging current was selected
Troubleshooting:
Try again with a different charging
current; if the fault continues to be indicated, the
battery is probably defective.
Indicator:
F05
Meaning:
A battery terminal is disconnected;
The equipment switches off and a warning signal will
sound for 25 seconds.
Troubleshooting:
Check the connection and select
the charging current again.
Indicator:
FUL
Meaning:
The battery is fully charged, the battery
voltage remains constant, the battery remains fully
charged.
Notes:
앬
In some cases the charging process is
completed very quickly and the battery is not
able to provide the quoted power output. The
battery has lost some of its capacity and must be
replaced.
앬
If the battery is nearly fully charged, a lower
value than the set charging current is indicated.
앬
If the battery you want to charge has an internal
cell short circuit, the LED FAULT will light up.
Check the battery voltage with a voltmeter. If the
voltage is under 12V, the battery will probably
13
GB
Anleitung BT_BC_12_D_SE_SPK1:_ 18.02.2009 7:22 Uhr Seite 13