background image

5

GB

Important!

When using equipment, a few safety precautions
must be observed to avoid injuries and damage.
Please read the complete operating manual with due
care. Keep this manual in a safe place, so that the
information is available at all times. If you give the
equipment to any other person, give them these
operating instructions as well.
We accept no liability for damage or accidents which
arise due to non-observance of these instructions
and the safety information.

1. Safety regulations

 

Caution!

In stagnant water bodies, garden ponds, dams
and their surrounding areas the unit may only be
used with an earth-leakage circuit breaker with
an actuating rated current of up to 30 mA
(according to VDE 0100 Part 702 and 738).

The equipment is not designed for use in
swimming pools and paddling pools of any kind
or other bodies of water in which people or
animals may be present during operation. It is
prohibited to operate the equipment if a person
or animal is in the danger area. Ask your
electrician!

This equipment is not designed to be used by people
(including children) with limited physical, sensory or
mental capacities or those with no experience and/or
knowledge unless they are supervised by a person
who is responsible for their safety or they have
received instructions from such a person in how to
use the equipment safely. Children must always be
supervised in order to ensure that they do not play
with the equipment.

Important!

Before you put the equipment into operation,
arrange for a specialist to check that the
- earthing
- protective multiple earthing
- residual-current operated circuit-breaker circuit
comply with the safety regulations of the power
supply company and work correctly.

The electrical plug-in connections must be
protected from wet conditions.

If there is a risk of flooding, place the plug-in
connections in an area which is safe from
flooding.

Strictly avoid pumping aggressive liquids and
abrasive substances.

Protect the equipment from frost.

Protect the equipment from dry running.

Take suitable measures to keep the equipment
out of the reach of children.

 

CAUTION!

Read all safety regulations and instructions.

Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.

Keep all safety regulations and instructions in a
safe place for future use.

2. Layout (Fig. 1)

1. Handle
2.  Integrated cable rewind
3.  Universal hose connection
4. Intake 

cage

5. Floating 

switch

6.  Screw for height adjustment

3. Items supplied

Open the packaging and take out the equipment
with care.

Remove the packaging material and any
packaging and/or transportation braces (if
available).

Check to see if all items are supplied.

Inspect the equipment and accessories for
transport damage.

If possible, please keep the packaging until the
end of the guarantee period.

IMPORTANT
The equipment and packaging material are not
toys. Do not let children play with plastic bags,
foils or small parts. There is a danger of
swallowing or suffocating!

Original operating instructions

Safety instructions 

Anleitung_RG_DP_7525 N_SPK7:_  10.05.2010  8:25 Uhr  Seite 5

Summary of Contents for 41.706.12

Page 1: ...t Original operating instructions Dirty Water Pump Art Nr 41 706 12 I Nr 11010 RG DP 7525 N Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 1...

Page 2: ...2 Read and follow the operating instructions and safety information before using for the first time Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 2...

Page 3: ...3 2 1 3 1 3 5 6 2 4 5 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 3...

Page 4: ...4 4 25mm 1 33 3mm 1 38mm 1 1 2 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 4...

Page 5: ...ut the equipment into operation arrange for a specialist to check that the earthing protective multiple earthing residual current operated circuit breaker circuit comply with the safety regulations of...

Page 6: ...height OFF min approx 5 cm 6 Before putting the equipment into operation 6 1 Installation The equipment can be installed either Stationary with rigid tubing or Stationary with a flexible hose line Not...

Page 7: ...ore water is emitted from the discharge line 8 Replacing the power cable If the power cable for this equipment is damaged it must be replaced by the manufacturer or its after sales service or similarl...

Page 8: ...s out of children s reach in a dark and dry place at above freezing temperature The ideal storage temperature is between 5 and 30 C Store the electric tool in its original packaging 8 GB Anleitung_RG_...

Page 9: ...ficient pumping rate Intake sieve clogged Performance reduced due to heavily contaminated and abrasive water impurities Clean intake sieve Clean equipment and replace wear parts The equipment switches...

Page 10: ...the demand to return electrical devices As an alternative to returning the electrical device the owner is obliged to cooperate in ensuring that the device is properly recycled if ownership is relinqu...

Page 11: ...any other means in whole or in part of documentation and papers accompanying products is permitted only with the express consent of ISC GmbH Technical changes subject to change Anleitung_RG_DP_7525 N...

Page 12: ...12 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 12...

Page 13: ...13 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 13...

Page 14: ...14 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 14...

Page 15: ...orce or external influences e g damage caused by the device being dropped and normal wear resulting from proper operation of the device The guarantee is rendered null and void if any attempt is made t...

Page 16: ...EH 05 20010 01 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 16...

Reviews: