7. Operation

You can put the equipment into operation after you
have thoroughly read the installation and operating
instructions. Pay attention to the following points:

Make sure that the equipment is set up securely.

Check that the discharge line is fitted correctly.

Make sure that the electrical connection is 240 V
~ 50 Hz.

Check that the electrical socket-outlet is in good
working order.

Make sure that no moisture or water can ever
reach the power connection.

Make sure that the equipment does not run dry.

Setting the ON/OFF switching point:

The ON/OFF switching point can be infinitely
adjusted with the height adjustment facility. For this
purpose you must first slacken the screw (Fig. 2,
Point 6). The switching differential can be infinitely
adjusted by extending or shortening the floating
cable.

The floating switch must be fitted so that the
switching point height: ON and the switch point
height: OFF can be reached easily and with little
force. Check this by placing the equipment in a
container filled with water and carefully raising
and lowering the floating switch with your hand.
You can then see whether the equipment
switches on and off.

Make sure that the distance between the floating
switch head and the cable holder is not too small.
If the distance is too small, there is no guarantee
that the equipment will work correctly.

When adjusting the floating switch, make sure
that the floating switch does not touch the bottom
before the equipment is switched off. Important!
Risk of dry running.

Manual operation:

Mount the float switch as illustrated in Figure 3 so that
the device runs continuously.  In this mode the
equipment may be used only under supervision to
avoid dry running. The equipment must be switched
off (pull out the power plug) as soon as no more water
is emitted from the discharge line.

8. Replacing the power cable

If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.

9. Cleaning, maintenance and

ordering of spare parts

Important!

Unplug the power plug prior to any maintenance
work.

For mobile applications, the equipment should be
cleaned with clear water after every usage.

For stationary installation, it is recommended that
you check the floating switch for proper
functioning every three months.

Use a water jet to remove any lint or fibrous
particles that may have become trapped in the
housing.

Remove sludge from the shaft bottom and clean
the shaft walls every 3 months.

Use clear water to remove deposits from the
floating switch.

9.1 Cleaning the paddle wheel

If a lot of deposits collect in the housing, the bottom
part of the equipment must be dismantled as follows:
1.  Disconnect the intake cage from the housing.
2.  Clean the paddle wheel with clear water.

Important! 

Do not put down or rest the

equipment on the paddle wheel!

3.  Assemble in reverse order.

9.2 Maintenance

There are no parts inside the equipment which 
require additional maintenance.

9.3 Ordering replacement parts:

Please quote the following data when ordering
replacement parts:

Type of machine

Article number of the machine

Identification number of the machine

Replacement part number of the part required

For our latest prices and information please go to
www.isc-gmbh.info

10. Disposal and recycling

The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.

Anleitung_RG_DP_7525 N_SPK7:_  10.05.2010  8:25 Uhr  Seite 7

Summary of Contents for 41.706.12

Page 1: ...t Original operating instructions Dirty Water Pump Art Nr 41 706 12 I Nr 11010 RG DP 7525 N Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 1...

Page 2: ...2 Read and follow the operating instructions and safety information before using for the first time Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 2...

Page 3: ...3 2 1 3 1 3 5 6 2 4 5 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 3...

Page 4: ...4 4 25mm 1 33 3mm 1 38mm 1 1 2 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 4...

Page 5: ...ut the equipment into operation arrange for a specialist to check that the earthing protective multiple earthing residual current operated circuit breaker circuit comply with the safety regulations of...

Page 6: ...height OFF min approx 5 cm 6 Before putting the equipment into operation 6 1 Installation The equipment can be installed either Stationary with rigid tubing or Stationary with a flexible hose line Not...

Page 7: ...ore water is emitted from the discharge line 8 Replacing the power cable If the power cable for this equipment is damaged it must be replaced by the manufacturer or its after sales service or similarl...

Page 8: ...s out of children s reach in a dark and dry place at above freezing temperature The ideal storage temperature is between 5 and 30 C Store the electric tool in its original packaging 8 GB Anleitung_RG_...

Page 9: ...ficient pumping rate Intake sieve clogged Performance reduced due to heavily contaminated and abrasive water impurities Clean intake sieve Clean equipment and replace wear parts The equipment switches...

Page 10: ...the demand to return electrical devices As an alternative to returning the electrical device the owner is obliged to cooperate in ensuring that the device is properly recycled if ownership is relinqu...

Page 11: ...any other means in whole or in part of documentation and papers accompanying products is permitted only with the express consent of ISC GmbH Technical changes subject to change Anleitung_RG_DP_7525 N...

Page 12: ...12 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 12...

Page 13: ...13 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 13...

Page 14: ...14 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 14...

Page 15: ...orce or external influences e g damage caused by the device being dropped and normal wear resulting from proper operation of the device The guarantee is rendered null and void if any attempt is made t...

Page 16: ...EH 05 20010 01 Anleitung_RG_DP_7525 N_SPK7 _ 10 05 2010 8 25 Uhr Seite 16...

Reviews: