GB
- 30 -
11. Charger indicator
Indicator status
Explanations and actions
Red LED Green LED
O
ff
Flashing
Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
On
O
ff
Charging
The charger is charging the battery pack in quick charge mode. The char-
ging times are shown directly on the charger.
Important!
The actual charging times may vary slightly from the stated
charging times depending on the existing battery charge.
O
ff
On
The battery is charged and ready for use.
The unit then changes over to gentle charging mode until the battery is
fully charged.
To do this, leave the rechargeable battery on the charger for approx. 15
minutes longer.
Action:
Take the battery pack out of the charger. Disconnect the charger from the
mains supply.
Flashing
O
ff
Adapted charging
The charger is in gentle charging mode.
For safety reasons the charging is performed less quickly and takes more
time. The reasons can be:
- The rechargeable battery has not been used for a very long time.
- The battery temperature is outside the ideal range.
Action:
Wait for the charging to be completed; you can still continue to charge the
battery pack.
Flashing
Flashing
Fault
Charging is no longer possible. The battery pack is defective.
Action:
Never charge a defective battery pack.
Take the battery pack out of the charger.
On
On
Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature (approx. 20° C)
for one day .
Anl_Agillo_18_200_SPK13.indb 30
19.11.2021 08:33:53
Summary of Contents for 34.113.10
Page 5: ...5 9 10 11 4 13 14 12 K Klick Anl_Agillo_18_200_SPK13 indb 5 19 11 2021 08 33 18...
Page 6: ...6 19 17 18 16 3 2 15b H F K 15a Anl_Agillo_18_200_SPK13 indb 6 19 11 2021 08 33 23...
Page 7: ...7 20 22 M 21 23 N P 24 25 Anl_Agillo_18_200_SPK13 indb 7 19 11 2021 08 33 25...
Page 8: ...8 27 1 2 8 9 3 4 5 6 7 10 11 26 L Anl_Agillo_18_200_SPK13 indb 8 19 11 2021 08 33 27...
Page 176: ...GR 176 H 10 2x 3 A O B Anl_Agillo_18_200_SPK13 indb 176 19 11 2021 08 34 26...
Page 181: ...GR 181 19 30 30 20 15 21 7 7 1 Anl_Agillo_18_200_SPK13 indb 181 19 11 2021 08 34 27...
Page 183: ...GR 183 9 N 5 30 C 26 L M 10 Anl_Agillo_18_200_SPK13 indb 183 19 11 2021 08 34 28...
Page 185: ...GR 185 2012 19 Einhell Germany AG M Anl_Agillo_18_200_SPK13 indb 185 19 11 2021 08 34 28...
Page 186: ...GR 186 www Einhell Service com Anl_Agillo_18_200_SPK13 indb 186 19 11 2021 08 34 28...
Page 258: ...EH 11 2021 01 Anl_Agillo_18_200_SPK13 indb 258 19 11 2021 08 34 39...