45
EIP-3500
Checking the LAN
LAN communication is disabled even
though connecting the control PC with a
LAN cable. The LINK LED (green) does
not light up.
Are the connection of connecting cable
and the settings of IP address, sub-net
address and default gateway correct?
Check the connecting cable and LAN settings. If the
LAN settings are unknown, contact the network
administrator.
If the network settings cannot be saved, replace
IC8003 (EEP ROM) as it may be defective.
Note: When IC8003 (EEP ROM) is replaced, the MAC
address returns to default. Refer to "Resetting
after replacing IC8003 (EEP ROM)" to reset.
Are the network device (e.g. Hub)
between the control PC and EIP-3500
and cable normal?
Repair defective parts in the network.
When data is sent from the control PC, do
pins (30) and (31) of IC8201 (PHY
receiver) receive signals?
Check the peripheral circuit of J8201 (RJ-45 jack
with built-in transformer).
Check the PHY receiver IC8201 and the
peripheral circuits of the microprocessor
IC8001.
YES
NO
YES
NO
YES
NO
YES
Summary of Contents for EIP-3500
Page 50: ...8 7 10 9 6 5 4 3 2 1 A B C D E F G H 50 EIP 3500 BLOCK DIAGRAM...
Page 51: ...17 16 19 18 15 14 13 12 11 10 51 EIP 3500...
Page 52: ...8 7 10 9 6 5 4 3 2 1 A B C D E F G H 52 EIP 3500 OVERALL WIRING DIAGRAM...
Page 53: ...17 16 19 18 15 14 13 12 11 10 53 EIP 3500...
Page 56: ...8 7 10 9 6 5 4 3 2 1 A B C D E F G H 56 EIP 3500 MAIN Unit Side A...
Page 57: ...17 16 19 18 15 14 13 12 11 10 57 EIP 3500...
Page 58: ...8 7 10 9 6 5 4 3 2 1 A B C D E F G H 58 EIP 3500 MAIN Unit Side B...
Page 59: ...17 16 19 18 15 14 13 12 11 10 59 EIP 3500...
Page 60: ...60 6 5 4 3 2 1 A B C D E F G H EIP 3500 FORMATTER Unit Side A...
Page 61: ...61 6 5 4 3 2 1 A B C D E F G H EIP 3500 FORMATTER Unit Side B...
Page 62: ...62 6 5 4 3 2 1 A B C D E F G H EIP 3500 POWER BALLAS Unit Side A POWER BALLAST Unit Side B...
Page 84: ...EIP 3500...