2.  SYSTEM OUTLINE

2.1 Components

Probe socket

Freeze  interface / 

TV / VGA  interface

Power supply indicator

Battery charge indicator

Main unit

Probe

Power input interface

LED display

Keyboard

2.2 Parts of the Probe

3

1

2

Name

Function

1.  Acoustic lens

To convert electric signal to ultrasonic signal based on principle of converse piezoelectric 
effect. The ultrasonic signal, after entering the human body, is refl ected as echo wave and 
converted to electric signal again. The acoustic lens is on the probe surface. Supply ultrasonic 
coupling gel to the acoustic lens surface when performing ultrasonic diagnosis.

2. Cable

To connect the probe with the probe connector.

3.  Probe connector

To connect the probe with the ultrasonic diagnostic instrument.

Summary of Contents for MAGIC 500 PLUS

Page 1: ...USER MANUAL MAGIC 500 PLUS ULTRASOUND UNIT Item No 303790 TELEPHONE 49 7461 96 580 0 www eickemeyer com ...

Page 2: ...re such as fires earthquakes floods or lightning etc Damage or loss caused by not meeting the conditions of use specified by the system such as inadequate power supply incorrect installation or environmental conditions do not meeting the requirements Damage or loss caused by using the system outside the initial buy region Damage or loss caused by the system being purchased not by EICKEMEYER or its au...

Page 3: ...e below Symbols Words Connotation Danger Indicates an imminent danger that may result in personal death or serious injury if not avoided Warning Indicates a potential danger that may result in personal injury if not avoided Attention Indicates a potential danger or unexpected use condition that may result in light injury or property loss or affecting the use if not avoided Safety Symbols Symbols M...

Page 4: ...imits Storage and transport Humidity limitation Storage and transport Atmospheric pressure limitation Storage and transport Symbol for the marking of electrical and electronics devices according to Directive 2002 96 EC The device accessories and the packaging have to be disposed of waste correctly at the end of the usage Please follow Local Ordinances or Regulations for disposal ...

Page 5: ...16 5 7 Ultrasonic Probe Check Before and After Operation 16 5 8 Main Unit Check Before and After Operation 16 5 8 1 Inspection Before Start up 16 5 8 2 Inspection After Start up 17 5 9 System Reset 17 6 Functional Operation 18 6 1 Startup and Shutdown 18 6 2 System Functions Setting 18 6 2 1 Time Setting 18 6 2 2 TV Mode Setting 18 6 2 3 Key Sound Setting 18 6 2 4 Screensaver Setting 18 6 2 5 Imag...

Page 6: ...e Check Lists 25 6 12 3 Transfer Check Lists to Workstation 25 6 13 Obstetric List Management 25 6 13 1 Save and View Obstetric List 25 6 13 2 Delete Obstetric Lists 25 6 13 3 Transfer Obstetric Lists to Workstation 25 7 General Measurement 26 7 1 Distance Measurement 26 7 2 Circumference Area Volume Measurement 26 Circumference Area Volume Measurement with Ellipse Method 26 Circumference Area Mea...

Page 7: ... Ultrasound Workstation Software 35 10 5 Change the Language for Ultrasound Workstation Software 35 11 System Maintenance 36 11 1 Maintenance by Users 36 11 1 1 System Cleaning and Disinfection 36 11 1 2 Use and Maintenance for the Rechargeable Battery 37 11 2 Replace the Fuse 39 11 3 Replacement of Power Supply Cord 39 11 4 Troubleshooting 39 11 5 Periodic Safety Checks 40 12 Storage and Transpor...

Page 8: ...selection function Frequency conversion function Frame correlation function Image post process function Edge enhancement function Single point multi point focusing function Local zooming function Image freeze unfreeze Vertical horizontal reverse Color display function Puncture guide Image filter function Save image by one key Ultrasound workstation manages image and data Case information image anno...

Page 9: ...robe 3 1 2 Name Function 1 Acoustic lens To convert electric signal to ultrasonic signal based on principle of converse piezoelectric effect The ultrasonic signal after entering the human body is reflected as echo wave and converted to electric signal again The acoustic lens is on the probe surface Supply ultrasonic coupling gel to the acoustic lens surface when performing ultrasonic diagnosis 2 Ca...

Page 10: ...mages data to the ultrasound workstation exchange measurement start end points etc 2 Main menu Save image read image cine loop 3 Confirm 4 Freeze Unfreeze 5 Direction Keys 6 Quit 7 Power switch 3 SYSTEM CONFIGURATION 1 Main unit 1 unit 2 6 5 MHz animal transrectal linear array probe 1 PC 3 Power adapter 1 PC 4 Armband 1 PC 5 Shutter release 1 PC 6 Plastic seal box 1 PC 7 Soft leather bag 1 PC 8 Str...

Page 11: ...n or flammable liquid such as alcohol are present Failure to do so may result in explosion Warning Avoid using this equipment with high frequency electric knifes high frequency therapy equipment or defibrillators and other electronic devices or an electric shock may occur to the patient Attention The mains voltage varies with different countries or regions Using radio transmitting equipment nearby t...

Page 12: ...l equipment to medical electrical equipment configures a medical system and is therefore responsible that the system complies with the requirements for medical electrical systems Attention is drawn to the fact that local laws take priority over the above mentioned requirements When more than one device is connected to use the accumulation of leakage current may cause the danger of security If in do...

Page 13: ...immediately and increase protective measures e g wear gloves before use Armband back ring Armband Extend your arm into the armband according to arrow direction or disconnect the armband to put on your arm the long end through the back ring Strain the armband and stick it firmly on the Velcro 3 Instrument used with the soft leather bag and hanging on the chest to use Installation Take out the instru...

Page 14: ...ttention 1 Turn off the ultrasonic system before disconnecting the probe Disconnecting the probe with system power on may damage the system or probe 2 Before disconnecting the probe place the cable and probe on a stable and leveled position so that the probe may not be damaged or injury person by unexpected fall 3 Freeze the instrument when instrument is start up without operation to increase of s...

Page 15: ...ull out the ultrasonic probe connector vertically when the knob touches the probe cable Turn it counterclockwise 5 3 Shutter Release Installation Install shutter release to Freeze interface TV VGA interface as shown in the figure Shutter release During operation you can freeze or unfreeze images using shutter release 5 4 Video Recorder Installation 1 Turn off the system connect the equipotential te...

Page 16: ...ing people by unexpected fallen make sure the power adapter is placed on the leveled desk 4 The operator must not touch signal input signal output and patient simultaneously 5 7 Ultrasonic Probe Check Before and After Operation Before and after ultrasonic diagnosis check if there are any exceptionalities on the surface of the probe or cable jacket such as peeling cracks bulge or if the acoustic le...

Page 17: ...by hand touching the probe to feel the temperature of the lens 4 Check the image to ensure trouble free display no excessive noise or flicker 5 Check the control panel to ensure normal operation condition 6 Check the instrument to ensure that the phenomenon of local high temperature will not appear Attention If the overheat acoustic lens is placed on the patient s skin heat injury may occur Thoroug...

Page 18: ...to achieve TV mode conversion between PAL and NTSC 5 Press key to confirm this setting and quit setting interface 6 2 3 Key Sound Setting 1 In real time mode press key to enter the main menu press direction keys to select Preset 2 Press keyto enter setting interface 3 Press direction keys to select Key Sound 4 Press direction keys to select between On and Off 5 Press key to confirm this setting and ...

Page 19: ...tting interface 6 2 8 RF Setting 1 In real time mode press key to enter the main menu press direction keys to select Preset 2 Press key to enter setting interface 3 Press direction keys to select RF 4 Press direction keys to select RF channels among 1 8 or select RF Off 5 Press key to confirm this setting and quit setting interface Note When setting RF it costs more time to select the channels 6 2 ...

Page 20: ...ng of B B B B M M and A 6 3 1 B Mode B mode is the basic operation mode after startup and a single framed B mode image is displayed Press key to freeze unfreeze the image In real time mode press key to exit B mode 6 3 2 B B Mode 1 In real time mode press key to enter B B mode 2 B B image switch Press key to enter the main menu press direction keys to move the cursor to B B Mode and then press dire...

Page 21: ...ld gain and direction key to reduce near field gain to control the gain in near field region 6 4 4 Far Field Gain Adjustment In real time mode press key to enter the main menu press direction keys to move the cursor to Far in the display area Press direction key to increase far field gain and direction key to reduce far field gain to control the gain in far field region 6 4 5 Dynamic Range Adjustment I...

Page 22: ... key to enter the main menu press direction keys to move the cursor to Color in the display area Press direction keys to achieve the conversion of eight kinds of colors including one kind of black and white 6 4 16 Image Freeze Unfreeze In real time mode press key to freeze the image in frozen status press key to unfreeze the image 6 5 Gain Adjustment in A Mode In real time A mode press key to ente...

Page 23: ... on the lower right corner of the screen 3 Press direction keys to select the image code need to be read out such as 003 4 Press key to read out the image stored in the frame 003 Img character shown at the lower right corner of the screen 5 Press key to quit reading status and press key to return to real time status Explanation When reading images choose the image code with 6 9 3 Delete the Image ...

Page 24: ...ght corner of the screen shows the relevant saved and played frames Press key to return to frozen status Press key unfreeze and quit playback status Note If the images appear abnormal there was not enough storage time and the images have not been fully stored 6 11 Text Input Operation steps 1 In real time B B B B M M mode freeze image the cursor is located on the Comment 2 Press key the cursor is ...

Page 25: ... real time status Note The specific functions of ultrasound workstation see Chapter Ten Ultrasound Workstation Software Instructions 6 13 Obstetric List Management 6 13 1 Save and View Obstetric List 1 In the B B B mode freeze the desired image 2 Obstetric results were obtained by obstetric measurement the results were saved to the main unit 3 Press direction keys to move the cursor to OB List pres...

Page 26: ...ys to move the mark to desired position press key to set the mark position as the starting point of the measurement 4 Press direction keys to move the mark to the end point of the measurement at the same time the elliptic curve appears 5 Press key the mark appears on the lower right of the image Hold down or key to change the minor axis of the ellipse to satisfy the test area The measured values a...

Page 27: ... The measured circumference and area values are automatically displayed at the built in mark C mm A 0 0 mm on the right part of the screen If continuously marks the thirty two point it directly appears trace on the screen the measured circumference and area values are automatically displayed at the built in mark C mm A 0 0 mm on the right part of the screen 5 Press key again the cursor will show r...

Page 28: ...ht area of the screen 6 Press key to exchange the starting and end point 7 Press key to finish the first measurement 8 Repeat the steps 3 7 to complete the multi group data measurement 9 Press key to quit measurement status for this animal 10 Press direction keys to select other measured animal press key to confirm repeat steps 3 7 to complete a variety of animal measurements 11 Continuously press ke...

Page 29: ...re the swine s backfat thickness and lean percentage Figure A mode interface 9 1 Measurement Items Name Abbreviation Unit Backfat thickness BF mm Loin thickness Loin mm Average thickness AVG mm Weight Weight kg Lean percentage Lean 9 2 Backfat Measurement 1 Choose the desired measurement site the trailing edge of shoulder P1 the tenth rib P2 the lumbosacral junction P3 10th or the last rib P3 P2 P...

Page 30: ...ge 37 300 kg 2 Put ultrasonic coupling gel to the appropriate site of swine s back in order to make good contact between the swine skin and the sound window The probe is placed against the skin of the animal and is kept perpendicular to the back move the probe gently make sure there are no air bubbles between the skin and probe Keep the swine quiet during the test you can feed the swine during the...

Page 31: ...the card in the package get EICKEMEYER ultrasound workstation software and install it 2 After finish the installation set up the phone 1 Go to Settings tap Display tap Font size to adjust text size on screen In order to display the complete text you should select Normal 2 Go to Settings tap Permissions to enter permission interface tap kx_station_v and open the permission 3 After finishing the opera...

Page 32: ...age stored in frame 004 is transferred to ultrasound workstation Batch images transfer Freeze the image press key to transfer all the stored images to the ultrasound workstation Note When transferring single or multiple images to the ultrasound workstation with WiFi if the image cannot be transferred the screen prompts Poor network environment please try again later Wait until the network is good ...

Page 33: ...ckbox in front of the search field 2 After setting the search conditions tap to get the check list of queries tap to give up the inquire 3 According to the query conditions to get the desired result then tap inquire to enter the query dialog box the checkbox is not selected click default display all lists Import check list In the check list interface click import click the database to import the sa...

Page 34: ...port the saved database into the current obstetric list Generate report In the obstetric list interface click report the obstetric list is generated as a report Empty the obstetric list In the obstetric list interface click empty to delete all obstetric lists 10 3 2 4 Images and Data on the Workstation Transfer to U Disk 1 Open the workstation software 2 Insert the U disk into the USB port of the ...

Page 35: ...S such as 1712250 3 When the network is disconnected the wireless signal icon on the MAGIC 500 PLUS screen disappears 10 4 2 Start Using PC side Ultrasound Workstation Software The function for PC side ultrasound workstation software kx_station_v is similar to the mobile workstation including image view check list management obstetric list management The following describes the differences 1 In th...

Page 36: ...ean the probe 1 Must wear sterilized gloves to prevent possible infection 2 Rinse the probe with water or soapy water to remove all contaminants or use a soft urethane sponge to wipe the probe Do not use brushes as this may damage the probe 3 After finishing the rinsing use a sterilized cloth or gauze to wipe the water on the surface of probe Do not dry the probe by heating it 2 High level disinfec...

Page 37: ...cracks or drop off 2 The sound window of probe is thin ensure that there are no any abnormity on the sound window such as scuffing cracks peeling bulge and drop off 4 Clean the probe cable and its connector 1 Clean the probe cable and its connector with soft dry cloth 2 In case of die hard blots clean with soft cloth dipped in moderate detergent and then air dry it 5 Clean the LED screen Use a soft...

Page 38: ...chanically shake the battery which will lead to leakage explosion or fire 7 Do not insert the battery with nail or other spiculate objects do not hammerblow or trample the battery which will lead to leakage explosion or fire 8 Do not weld the battery terminal directly which will lead to leakage explosion or fire 9 Do not disassemble the battery in any way which will lead to leakage explosion or fire 1...

Page 39: ... abnormity occurs contact EICKEMEYER for support If the following problems occur on starting up the machine try to make corrections following the method in the table If the problem remains unsolved contact EICKEMEYER for support Trouble Correction Power supply indicator is off and no screen display is present when starting the machine 1 Check power supply 2 Check power cable and plug 3 Check power...

Page 40: ...device case should have adequate space from ground walls and ceiling of the warehouse 2 Environment requirement Ambient temperature 20 C 55 C Relative humidity 30 93 without condensation Atmospheric pressure 700 hPa 1 060 hPa The warehouse should be well ventilated and free of direct sunlight and corrosive gas 3 Shockproof measures have been taken inside the packing case to allow for transport by ...

Page 41: ...41 USER MANUAL MAGIC 500 PLUS ULTRASOUND UNIT NOTES T 49 7461 96 580 0 F 49 7461 96 580 90 export eickemeyer com www eickemeyer com ...

Page 42: ...42 USER MANUAL MAGIC 500 PLUS ULTRASOUND UNIT NOTES T 49 7461 96 580 0 F 49 7461 96 580 90 export eickemeyer com www eickemeyer com ...

Page 43: ...43 USER MANUAL MAGIC 500 PLUS ULTRASOUND UNIT NOTES T 49 7461 96 580 0 F 49 7461 96 580 90 export eickemeyer com www eickemeyer com ...

Page 44: ...R Sp z o o Al Jana Pawła II 27 00 867 Warszawa T 48 22 185 55 76 F 48 22 185 59 40 info eickemeyer pl www eickemeyer pl DENMARK EICKEMEYER ApS Lysbjergvej 6 Hammelev 6500 Vojens T 45 7020 5019 F 45 7353 5019 info eickemeyer dk www eickemeyer dk NETHERLANDS EICKEMEYER B V Bedrijventerrein Pavijen West Bellweg 44 4104 BJ Culemborg T 31 345 58 9400 info eickemeyer nl www eickemeyer nl ITALY EICKEMEYE...

Reviews: