20
Instructions for Use
Separation capacity (for 90° cuts):
Cutting height:
80 mm
100 mm
120 mm
Cutting length:
250 mm*
210 mm
150 mm
* with rigid additional stop
Adjustment clamping range:
The original spacing or interval between the vise and the guide plate is 70 –
230 mm. If your work requires wider spacing or interval, proceed as follows
to change the spacing or interval. Remove the two hex bolts which secure
the guide plate. Move the guide plate as shown in Fig.8
and secure it
using the hex bolts. The following interval settings are possible: 30 – 190
mm ore 0 – 160 mm.
To work with reduced dust – replace the adjustable angled stop near
the dust hood.
Increase of the cutting length
The cutting length can be increased by switching the stop to 250mm.
Unscrew the adjustable angled stop from the sawing table and replace the
same by the rigid stop (use socket wrench SW 8) (Fig.9).
The rigid stop has to be screwed to the rearmost boring.
CAUTION:
Remember that narrow workpieces may not be secured
safely when using the two, wider interval settings.
Setting for desired cutting angle
To change the cutting angle, loosen the two hex bolts which secure the
guide plate. Move the guide plate to the desired angle (0° – 45°) and tighten
the hex bolts securely (Fig.10).
Securing workpieces
By turning the vise handle counterclockwise and then flipping the vise nut to
the left, the vise is released from the shaft threads and can be moved rapidly
in and out. To grip workpieces, push the vise handle until the vise plate
contacts the workpiece. Flip the vise nut to the right and then turn the vise
handle clockwise to securely retain the workpiece (Fig.11).
CAUTION:
Always set the vise nut to the right fully when securing the workpiece.
Failure to do so may result in insufficient securing of the workpiece.
This could cause the workpiece to be ejected or cause a dangerous
breakage of the wheel.