26
Exchanging the plastic emptying bag
- Set switch to position >AR<.
Folded filter cartridges are cleaned automatically.
Residual dust in the filters falls into the bag.
- Switch off vacuum cleaner.
- Disconnect mains plug.
- Wear appropriate breathing mask.
- Remove suction hose.
- Close off intake socket with cap.
- Open side latches.
- Carefully close the PE emptying and disposal bag with the enclosed
sealing tape.
- Carefully pull the flange off the intake socket and close off the flange.
-
Carefully remove the PE emptying and disposal bag from the container.
- Dispose of gathered material in accordance with legal requirements.
Cleaning
Clean the tank and accessories with water. Wipe the top section (1) with e
damp cloth.Allow the tank and the accessories to dry.
Servicing
Before the beginning of maintenance or repair works
you have to disconnect the plug from the mains!
If the suction output of the unit decreases and is not improved after the filter
cassettes (12) are cleaned,(assuming the tank (6) is empty and the fleece
filter bag (13) has been exchanged), then it is time to exchange the filter
cassettes (12).
Apply the vibration function to the filter cassettes (12) again before
exchanging them. Use a coin or another similar object to turn the catch (5)
and the locking bar (4) 90° in an anticlockwise direction and then press the
locking bar (4) backwards. Fold up the hood and lift out the filter cassettes
(12). Immediately seal the removed filter cassettes in a dust-proof plastic
bag and dispose of as per the statutory regulations. Insert new filter
cassettes. Fold down the hood again and exert a little pressure to click it
back into position.
If the
motor protection filter
is soiled, this is an indication that the
filter cassettes are defective.
Please exchange both filter cassettes. Wash out the motor
protection filter under running water, dry and re-insert.