N.B Disconnect Mains Before Alarm Head Removal
After disconnecting the mains power supply, it is now safe to remove the Alarm from
its base. Using a screwdriver, insert into the removal slot on the side of the Alarm.
Push the lower half of the Alarm away from the screwdriver, in the direction of the
arrow on the cover (see Figure 1 below).
CAUTION:
The existing hard-wired interconnection may need to be disconnected
at this point by disconnecting the interconnect (black) wire from the terminal block
(refer to the Installation section in the Alarm instruction manual). If a hard-wired
connection and an RF connection exist between the
SAME
two Alarms, a
continuous alarm loop signal will occur.
4
Installation and House Coding
Figure 1