300781 • 1/2019 • H.S.
26 of 70
Operating Instruction
High Pressure Cleaner cold water, mobile
Series 3x3
3 Pr
oduct information
3.14
Technical data
3.14.1
High Pressure Cleaner cold water, mobile - Series 3x3
Device version Standard and Premium
KD623
KD823
KD940
KD940-F
Electrical connection
Mains voltage
V
230
230
400 - 415
400 - 415
Phase
~
1
1
3
3
Mains frequency
Hz
50
50
50
50
Connected load
kW
2,9
3,2
5,2
4,5
Current (max.)
A
14,2
14,7
9,1
8,1
Degree of protection
IP
IPX5
IPX5
IPX5
IPX5
Mains fuse (slow-blowing)
A
16
16
3 x 16
3 x 16
Residual current circuit breaker
(max. allowed residual current)
mA
30
30
30
30
Extension cable up to 20 m
Wires
3 x
3 x
5 x
5 x
mm
2
2,5
2,5
2,5
2,5
Water connection
Max. feed pressure
bar
5
5
5
5
MPA
0,5
0,5
0,5
0,5
Max. feed temperature
° C
45
45
45
80
Minimum feed volume
l/min
15
15
15
15
Suction height
m
0
0
0
0
Performance data device
Nozzle size
---
035
045
045
060
Operating pressure
bar
30 - 160
30 - 140
30 - 190
30 - 130
MPA
3 - 16
3 - 14
3 - 19
3 - 13
Max. operating over-pressure
bar
180
165
210
150
MPA
18
16,5
21
15
Discharge capacity
l/h
300 - 600
300 - 720
300 - 840
300 - 840
Recoil force
trigger gun
N
29,8
33,5
42,2
35,0
Table 3 - 1
Technical data for High Pressure Cleaner cold water, mobile - Series 3x3