300781 • 1/2019 • H.S.
52 of 70
Operating Instruction
High Pressure Cleaner cold water, mobile
Series 3x3
6 Operation
1
1 Adjustment controller for setting the quantity of cleaning detergent
Fig. 6 - 5
Adjustment controller for quantity of cleaning detergent
(Version Standard)
6.5.3
Cleaning detergent operation with version Premium
CAUTION
Chemical dry run or inadmissible detergents can damage the device.
Only open the detergent control valve when the filter of the detergent
suction hose is fully inserted to the bottom of the detergent container.
Also make sure the container is sufficiently filled with approved
detergent.
Intake air or inadmissible detergents causes damage to seals and pumps.
For operation with cleaning detergents with the version Premium:
Provide external cleaning detergent container.
Fill or top up (if necessary) the detergent tank with approved deter-
gent.
Insert the filter of the detergent suction hose (see position number 11
in Fig. 3-3, Fig. 3-4 , Fig. 3-6 and/or Fig. 3-8) to the bottom of the
detergent container.
Initially set the detergent control valve (4, Fig. 6 - 1) into position „0“
Open the detergent control valve (counterclockwise) from position „0“
according to the desired quantity of detergent.
General Information
The more the detergent control valve is opened, the more amount of
detergent is sucked in. Depending on the application, set the dosage via
the detergent control valve.