English
25
. . . Primer does not work?
Cause Solution
Prefilter flap in prefilter Check the prefilter flap for pollution and, if required, clean it.
not closed. The prefilter flap must be unobstructed (see chapter 8.2, step 13).
Prefilter is filled with water. Empty prefilter, repeat priming. Priming only works with empty prefilter.
Check valve polluted/defective. Clean and, if required, replace the check valve (see chapter 8.3).
Cause Solution
No mains supply. Plug in to mains.
Shaft broken. Renew shaft (see list of spares).
Impeller missing or blocked by bits Fit impeller, clean pump chamber.
of gravel, shells or similar.
. . . Pump does not work?
. . . Filter performance has greatly deteriorated?
Cause Solution
Safety adapter lever position not correct. Check lever setting and adjust.
Safety adapter soiled. Remove safety adapter; open shut-off lever and clean openings
with
EHEIM
cleaning brush (no. 4005570).
Hose installation. Check that there are no kinks or marked narrowing of cross-section.
Hose installation soiled. Clean hose installation with
EHEIM
cleaning brush (no. 4005570).
Strainer blocked. Remove coarse dirt, clean strainer.
Filter media heavily soiled. Clean filter media.
Filter media filled into a net bag. Never put long-term filter media in net bags or nylon stockings. This
leads to a drastic reduction in pump performance within a short time.
Filter media not cleaned properly. When cleaning, remove the filter media from the filter media basket
and rinse through with lukewarm water (see
III
).
Filter media wrongly assembled. Check that filter media have been assembled correctly in the recom-
mended layers of filtering. Fill bottom filter insert to just under edge
with
EHEIM
MECH. Fill next filter inserts with
EHEIM
SUBSTRAT,
also to just under edge. Never place white filter pad under the handle.
Filter pad not renewed. Be sure to renew the filter pad each time you clean.
Pump is dirty. Clean pump chamber, cooling and lubrication channel with
EHEIM
cleaning brush set (no. 4009560).
Water is not circulating properly. Take filter into operation by priming (as described in the instructions).
Make sure that the water runback (delivery side) is above the surface
of the water during filling so that air is optionally bled from the device.
Too many accessories installed Connected accessories reduce filter performance. Check and remove
on the hose system. unnecessary accessories or operate via a separate water system.
Summary of Contents for professionel5e 450
Page 2: ...I ...
Page 3: ...II ...
Page 4: ...click 1 5 6 7 8 2 3 4 11 12 13 14 15 16 17 5 1 23 9 10 ...
Page 5: ...8 1 1 12 click 18 19 20 21 8 9 10 11 12 1 2x 22 23 1 1 2 2 3 4 5 6 7 8 2 1 16 1 2 3 4 5 6 ...
Page 6: ...8 9 10 7 11 13 14 8 3 1 11 9 10 11 1 2 3 4 5 6 8 12 15 16 7 prof 5e 2 3 2 3 ...
Page 17: ...Deutsch 17 siehe Seite 180 11 Technische Daten siehe Seite 181 12 Ersatzteile ...
Page 44: ...Zie pag 180 11 Technische gegevens Zie pag 181 12 Reserveonderdelen Nederlands 44 ...
Page 176: ...中文 8 3 清洁泵室 176 9 如果发生以下情况 该怎么办 5 8 2 8 3 ...
Page 177: ...中文 177 ...
Page 179: ...179 ...