English
13.
Attach the pre-assembled hose accessories (see
I
). to the aquarium.
14.
Cut the hoses (23) to length in ac-
cordance with the clearance between the filter and the aquarium and plug onto the accessories.
15.
Plug the
hoses (23) onto the safety adapter (13) down to the limit stop.
16.
Attach the hose locking device (11).
17.
Push the safety adapter (13) into the pump head (17) until it audibly latches.
18.
Set the locking lever (12) to
„ON“
.
19.
Assure the the nozzle pipe (25) is suspended above the water surface.
20.
Rapidly press the suction
aid (16) several times consecutively until the filter tank (10) automatically fills with water (no water must be pre-
sent in the prefilter!).
21.
Plug in the power supply unit (28) at the pump head (17).
22.
Plug in the power cable
(30).
23.
For bleeding, press the suction aid (16) once or twice and push the nozzle pipe (25) to the desired
position.
System Requirements
WLAN-capable end device (smartphone, tablet, notebook etc.)
6.1 Creating a Network
Put the exterior filter into operation by plugging in the mains plug. The status LED of the pump head lights up:
• White flashing LED: Network is being sought or created.
• Blue LED: The controller has created a new network.
6.2 Connecting to the WLAN network #EHEIM Filter_XXXXXXXX
Open the network settings of the end device, for example, notebook, tablet or smartphone, and connect to the
WLAN network, #EHEIM Filter_XXXXXXXX..
6.3 Calling up the website
Open the internet browser and call up the web address
http://eheimdigital.local
or
http://192.168.1.1.
6.4 Start the Configuration
Select the desired language in the language selection field and proceed with the initial configuration. Follow the
instructions accordingly. Detailed instructions can be downloaded via QR code on the title page or under
www.eheim.com
.
6. Operation
22
7. Thermofilter
professionel 5e
- 600 T, Typ 2378 (
see IV)
Only thermofilter:
33.
Control indicator („ON“ / „OFF“)
34.
LED indicator in Celsius (°C)
35.
Status indicator for
target temperature in Celsius (°C)
36.
Pushbutton
37.
Display in Fahrenheit (°F)
38.
Heating spiral.
Setting range of the target temperature 18° – 34°C 64° – 93°F
Factory setting of the target temperature 24°C / 75°F
Factory setting of the temperature unit Celsius (C) / Fahrenheit (F)
Switching hysteresis
±
1°C
Power consumption 210 W
Voltage see type plate on canister bottom
A
Control indicator (33) is not lit up = Heater off.
B
Control indicator (33) is lit up = Heater is heating.
7.1 Operation
C
The actual temperature is displayed. Indicator is lit up, status indicater of target temperature (35) is off.
7.2 Display mode
Summary of Contents for professionel5e 450
Page 2: ...I ...
Page 3: ...II ...
Page 4: ...click 1 5 6 7 8 2 3 4 11 12 13 14 15 16 17 5 1 23 9 10 ...
Page 5: ...8 1 1 12 click 18 19 20 21 8 9 10 11 12 1 2x 22 23 1 1 2 2 3 4 5 6 7 8 2 1 16 1 2 3 4 5 6 ...
Page 6: ...8 9 10 7 11 13 14 8 3 1 11 9 10 11 1 2 3 4 5 6 8 12 15 16 7 prof 5e 2 3 2 3 ...
Page 17: ...Deutsch 17 siehe Seite 180 11 Technische Daten siehe Seite 181 12 Ersatzteile ...
Page 44: ...Zie pag 180 11 Technische gegevens Zie pag 181 12 Reserveonderdelen Nederlands 44 ...
Page 176: ...中文 8 3 清洁泵室 176 9 如果发生以下情况 该怎么办 5 8 2 8 3 ...
Page 177: ...中文 177 ...
Page 179: ...179 ...