19
English
6. Maintenance
ATTENTION! Electrocution!
▶ Before all maintenance work, remove the mains plug.
CAUTION! Material damage.
▶ Do not use hard objects or aggressive cleaning agents for cleaning.
The following sections describe maintenance work necessary for optimum and fault-free operation.
Regular maintenance prolongs the service life and secures functionality of the pump over a long
period.
Cleaning the water feature nozzle and telescopic pipe
1. Unscrew the telescopic pipe.
2. Remove the water feature nozzle.
3. Clean the telescopic section and water feature nozzle under running water.
Cleaning the filter housing
1. Take the pump out of the water.
2. Remove the outlet spigot with the hose.
3. Unscrew the telescopic pipe.
4. Open the filter housing by pressing in the two side latches at the same time (⌦G1).
5. Take off the housing cover (⌦G2).
6. Press the unlocking head (⌦H1).
7. Pull the pump forwards out of the guide (⌦H2).
8. Clean the filter housing with a water jet.
9. Install the pump again in reverse order.
When assembling, make sure that the mains cable is guided correctly through the strain relief and the
housing opening (⌦l).
Cleaning the pump (1000 / 1500)
1. Open the filter housing (⌦G) and remove the pump (⌦H), see Cleaning the filter housing.
2. Unscrew the locking ring ② from the motor housing ① (⌦K).
3. Use a screwdriver to carefully prise the pump cover ⑤ uniformly to the front out of the motor hous-
ing.
4. Pull the impeller ④ out of the motor housing.
5. Install the pump again in reverse order.
‧ When assembling, make sure that the bearing bushings ③ are inserted correctly in the pump cover
and in the motor housing.
‧ When assembling, make sure that the locking ring engages easily when being screwed on.
Cleaning the pump (2500 / 3500)
1. Open the filter housing (⌦G) and remove the pump (⌦H), see Cleaning the filter housing.
2. Unscrew the locking ring ② from the motor housing ① (⌦K).
Summary of Contents for 5100010
Page 5: ...5 E G H min max max min F...
Page 6: ...6 I J L K PLAY2500 PLAY3500 PLAY1000 PLAY1500...
Page 91: ...91 PLAY 1000 1500 2500 3500 1 x I A A IP68...
Page 92: ...92 A 2 35 C 3 8 A...
Page 93: ...93 EHEIM 30...
Page 94: ...94 H05RN F3G0 75 DIN VDE 0620 30 4 1 B 2 3 A 1 C 2 D 3...
Page 95: ...95 5 1 20 2 J 3 4 BUBBLE 5 1 1 F 2 2 1 6 1 2 3...
Page 96: ...96 1 2 3 4 G1 5 G2 6 H1 7 H2 8 9 I 1000 1500 1 G H 2 K 3 4 5 2500 3500 1 G H 2 F 3 4 5 F...
Page 97: ...97 7 PLAY1000 1 2 1 EHEIM 8 1 2 3 2012 19 WEEE...
Page 99: ......