background image

FIGURE B:  CONTACT  PHASE INDENTIFICATION  MARKINGS 

GROUND CONTACT 

LINE CONTACT 

IDENTIFICATION 

MARKING 

TYP 

CLASS II INTERLOCKED 

RECEPTACLE ASSEMBLY  --� 

(P OWERTITE COMPATIBLE) 

FUSES SHOWN 

NOT  INCLUDED 

WITH UNIT 

PADLOCK 

HOLE 

FUSE COVER 

CUT 

AWAY

TO SHOW 

FUSE HOLDER 

(ASSEMBLY VIEW WITH COVER REMOVED)  - UNIT SHOWN IS CAT. NO. MD2SR1034F 

Rev.  C  07 /08/04 

Page 3 

Summary of Contents for Appleton MD2SR Series

Page 1: ...S VOLTS AMPERES 250 600 30 250 600 30 250 600 60 250 600 60 250 600 100 250 600 100 FIGURE A g H P RATING CATALOG SWITCH AC NUMBERS TYPE STANDARD MAX MD2SR3023F FUSED 7 5 20 MD2SR3034F MD2SR3023U NON...

Page 2: ...NG CURRENT RATING 30 30 30 30 60 60 60 60 100 100 100 100 TORQUE LB IN 40 45 50 Electrical power must be turned OFF before and during installation and maintenance Failure to do so may result in seriou...

Page 3: ...NTACT IDENTIFICATION MARKING TYP CLASS II INTERLOCKED RECEPTACLE ASSEMBLY POWERTITE COMPATIBLE FUSES SHOWN NOT INCLUDED WITH UNIT PADLOCK HOLE FUSE COVER CUT AWAY TO SHOW FUSE HOLDER ASSEMBLY VIEW WIT...

Page 4: ...OVED UNIT SHOW IS CAT NO MD2SR1034F ______ 16 7 42 3 CM CONDUIT ENTRY 0 3 0 7 6 CM 11 0 27 9 CM I CATALOG NUMBER DIMENSION A MD2SR3023F MD2SR3023U MD2SR3034F MD2SR3034U MD2SR6023F 19 3 MD2SR6023U 48 9...

Page 5: ...erring to FIGURE C loosen the housing Cover Bolts G but do not attempt to remove them completely from the Cover because they are designed to be captive B The Cover is now free to swing open on its fac...

Page 6: ...se Holder Use only sand filled non renewable Class J Fuses F Wire Guide allows wiring to be run from the top or bottom of the Enclosure to the opposite end of the Enclosure without interference with t...

Page 7: ...Housing Referring to FIGURE C loosen line side Lugs Screws of the Disconnect Switch and remove line side wires from the Switch On non fused units loosen load side Lug Screws J of the Disconnect Switch...

Page 8: ...rew Cover onto the Receptacle Housing until screw cover gasket is firmly seated against the receptacle housing face Replace the receptacle housing screw secure the free end of the Screw Cover chain to...

Page 9: ...BLY 5 100 FUSE COVER 59351031000 1 ASSEMBLY 6 30 CLASS II RECEPTACLE 59312775000 1 ASSEMBLY 30 AMP 2 WIRE 3 POLE 7 30 CLASS II RECEPTACLE 59312766000 1 ASSEMBLY 30 AMP 3 WIRE 4 POLE 8 60 CLASS II RECE...

Page 10: ...Clean interior of all foreign materials 6 Cover Bolts G must be tightened to 25 30 lb ft torque 7 Make sure the Receptacle Assembly Nameplate located on the outside of the cover remains clean and legi...