background image

Connect to EGi-1111-002

Connect with EGi-1111-0002

User: egi

Password: 

••••

 

Remember password

Accept

Cancel

Gateway 1111 - Millennium IP

13

To load audio files in the unit, write the following in Windows 
Explorer:

\\EGi-1111-0_ _ _\music

The password will be requested, by default:
User: 

egi

Password: 

1234

– 

Analogue input:

 ON/OFF.

– 

Analogue input in use:

 indicates which input signal will switch to analogue audio, PIN input or 

XLR activated by the RELAY_IN input.

– 

General volume:

 unit audio output level in %. The maximum nominal value is 88%. This is the 

value for which an input at maximum nominal value would not be distorted. A higher value could 
distort depending on the input level . 0% = -

 dB;  88% = 0 dB;  100% = +1.1 dB.

The MPD can be controlled from a mobile or PC by means of freely available MPD clients, such as:
–  PC: Auremo
–  Android: DroidMPD
–  IOS: MPoD

In this work mode the 1111 unit plays or obtains the audio from the network independently, with the PC, 
mobile or tablet acting as remote control. There can be more than one client controlling the MPD at the 
same time, and any changes are automatically displayed in all the clients. The MPD client can 
disconnect or switch off the mobile and the MPD will continue playing the configured playlist.

The DLNA/Airplay work mode is similar to audio Bluetooth but it operates via WiFi or Ethernet. The 
contents are played by mobile or PC and sent to the unit. If a call is received by the mobile or if the 
mobile leaves the area covered by WiFi, the audio will be lost. But remember that with this option 
mobile or tablet battery consumption will be greater.

• 

Audio streaming playing, which permits:
–  Playing radios over the Internet.
–  Receiving corporate audio from an external streaming server.
–  Receiving audio from a PC, sent with a streaming program such as VLC, Windows media player, 

Icecast2, Jamcast, etc.

–  Creating streaming with adverts and music, by programs such as Airtime.

• 

Playing audio from PC, tablet or mobile:
–  Android/PC: DLNA.
– Apple/iTunes: AirPlay-compatible.

The parameters are:
– 

ON/OFF audio player:

 to stop playing audio.

– 

Player volume (%):

 volume at which the audio is heard on the players. It is  separated from the general 

volume and is based on a percentage over dB. 0% = -

 dB;  88% = 0 dB;  100% = +1.1 dB. 

– 

Music player daemon parameters (MPD):

• 

Repeat playlist: the selected list will be repeated over and over again.

• 

Random play mode: the list will play audio files randomly.

• 

Automatic playlist: if this box is ticked, the selected playlist will be loaded every time the 1111 
unit is turned on, and it will be played automatically in the established list order (AutoPlay).

• 

Playlist file: a playlist can be selected for automatic start, out of those available in the music 
directory/playlists. Lists can be loaded directly from the PC into the file explorer or created with 
an MPD client from PC, tablet or mobile. They must have M3U format.

• 

DLNA: ON/OFF. This plays the audio from a DLNA device, such as PC, tablet and mobile based 
on Android or Windows. It does this through the MPD.

• 

Airplay: plays the audio from an Apple device, such as iPhone, iPad, MacOS, or from a PC with 
iTunes. It is separated from the MPD, but it is advisable to stop the MPD before playing music 
with Airplay.

– 

PIN output:

• 

ON: always active.

• 

OFF: always inactive.

– 

RELAY output:

• 

ON: always active.

• 

OFF: always inactive.

en

Summary of Contents for Millennium IP Series

Page 1: ...AirPlay compatible Gateway 1111 Millennium IP ...

Page 2: ...you have placed in us Thanks to this interface you will be able to send IP audio and voice anywhere in the world IMPORTANT To program and use this unit it must have a power supply of 15 V connection to an Ethernet or LAN network and it is advisable for you to have some knowledge of network programming Gateway 1111 Millennium IP en ...

Page 3: ...11 1111 system reset button 12 IN balanced audio input through 6 3 mm jack or female XLR connector 13 PIN IN audio and relay inputs referred to ground 4 via plug in terminal block 14 OUT balanced audio input through male XLR connector 15 PIN OUT audio and relay outputs potential free contact referred to ground 4 via plug in terminal block 16 15 V power input terminal block 17 Standard 15 V coaxial...

Page 4: ... RELAY IN and RELAY OUT will depend on the needs of each installation 1111 Configuration From a web browser enter the address of the name that appears on the label on the front of the unit for example http EGI 1111 0007 You will see the following image on the screen The Gateway 1111 can be programmed by entering the username and password which by default is Username egi Password 1234 If you have a...

Page 5: ... from multimedia equipment like smartphone table or PC 15 V power supply through terminal block or coaxial connector Audio input and output through XLR connectors or EGi PIN compatible terminal block 3VRMS AC 7V DC Output relay for amplifier control or auxiliar function Input relay for streaming control or auxiliar function EGI 1111 0007 Overview Network System Services Logout Help EGI 1111 0007 O...

Page 6: ...6 1 83 255 255 255 0 753 87 KB 2 00 MB 0 0 Local Network Protocol manual IPv4 Address 192 6 1 83 IPv4 Netmask 255 255 255 0 IPv4 Gateway optional 192 168 1 1 DNS Server optional 77 73 160 11 Save Revert Gateway 1111 Millennium IP 7 Network menu Network General is where network connection data are configured By default the network configuration is taken automatically from a DHCP server This is what...

Page 7: ...rmware In System Backup Flash firmware the configuration can be saved or retrieved and the unit s firmware updated In save restore you can save a copy of the unit s configuration in your PC This allows you to recover a known good configuration at any time To do so click the Generate archive button and select a location in a directory for your backup The Reset button allows the unit s default value...

Page 8: ...ennium IP Gateway 1111 Millennium IP 9 Services Millennium IP Work modes To configure the unit s work mode and the audio player settings enter Services Millennium IP The first parameter is the work Mode you wish to use SERVER The unit behaves as a server audio transmitter to the LAN network through Audio link CLIENT The unit behaves as client or audio receiver from the LAN network through Audio Li...

Page 9: ...n without compression is CD quality 44 1 KHz 16 bits The parameters are Audio server ON OFF to stop the audio transmission Channel number selected transmission channel between 1 and 10 it will transmit in multicast address 239 192 0 X where X is the channel number WORK MODES DEPENDING ON WHETHER IT IS INTEGRATED WITH MILLENNIUM OR USED SEPARATELY Mode 1 Integration with Millennium Decentralisation...

Page 10: ...ut REMOTE always transmit ON or always transmit OFF Input gain gain in dB that is analogically applied to the audio input before digitizing The nominal value is 6 dB The nominal audio input is 1 2 VRMS for the XLR input and 3 VRMS with 7 5 V activation of the PIN input If the audio level is lower gain must be applied correspondingly in order to reach the nominal input value The final buttons are u...

Page 11: ...l value is 88 for an input to be distorted at maximum nominal value The final buttons are used to Save to configure the parameters without rebooting the service The configured parameters will be used the next time the unit starts Save and apply to configure the parameters and reboot the service In the case of the server the unit must be rebooted completely and it will take another minute for the c...

Page 12: ...ablet battery consumption will be greater Audio streaming playing which permits Playing radios over the Internet Receiving corporate audio from an external streaming server Receiving audio from a PC sent with a streaming program such as VLC Windows media player Icecast2 Jamcast etc Creating streaming with adverts and music by programs such as Airtime Playing audio from PC tablet or mobile Android ...

Page 13: ... 12 Millennium VoIP Millennium IP Gateway 1111 Millennium IP Services VoIP Multicast For VoIP SIP and Multicast configuration enter Services Millennium VoIP the following screen will be shown The VoIP is configured on this screen both for direct connection or connection via a PBX and for Multicast Paging configuration NOTE For the VoIP service to work correctly the PLAYER or VoIP ONLY working mode...

Page 14: ...sion Recording time to operate with 3CX exchanges this value must be zero Local IP IP address of the PBX on the network External IP for Internet exchanges PIN output If the PIN output of the unit will always be active always inactive or will be activated with an incoming call It allows control of external amplifiers Relay output if the relay output of the unit will always be active always inactive...

Page 15: ...apply to configure the parameters and reboot the service In the case of the server the unit must be rebooted completely and it will take another minute for the changes to take effect Revert deletes the form and returns to previous initial values Logout In the Logout menu the online session is closed and the unit continues operating 16 If an audio link channel is required your unit in server mode t...

Page 16: ...La Muela Zaragoza Spain ATENCIÓN TÉCNICO COMERCIAL TECHNICAL SALES SERVICE Tel 34 976 404 677 e mail sat_consultas egiaudio com DPTO DE EXPORTACIÓN EXPORT DEPARTMENT Tel 34 976 405 356 Fax 34 976 405 354 e mail export egiaudio com DISTRIBUIDOR DISTRIBUTOR DELEGACIONES SALES OFFICES Delegación Centro C Juan de Mariana 19 local 20 28045 MADRID Spain Tel 91 506 24 18 e mail egimadrid egiaudio com Del...

Reviews: