61760V04-2012-09
Seite / Page 21 von / of 28
Later, as long as the unit is in the heating up phase and the material is already melted, you can re-
fill material. But be careful - do not throw material inside, danger of splashing and fire!
When high quantities of duplicating material are required, you can refill it until approx. 1.5 cm be-
low the margin of the cup. (Information: Material level up to the upper blade of the agitator corre-
sponds to approx. 4.5 kg, up to 1.5 cm below the margin of the cup corresponds to approx. 5.5 kg).
In any case, fill the unit (even when very small quantities are required) at least halfway because,
otherwise, the error protection circuit might actuate.
2.
Unit already filled with solidified duplicating material:
Please ensure that the level of the material is not higher than to the upper blade of the agitator.
The agitator has enough power to crush the solidified material, but would lift the cover and push
out material if the cup was overfilled.
4.4 Starting the device, program run
We presume that before initial operation you have already set the
programming described in the following or will be using the given set-
tings.
To start the unit the cover must be closed because, otherwise, a per-
manent tone will sound in case of intending to start the unit. Press the
button “Start” (T1).
A short description of the program run:
The unit immediately starts heating up. At the front plate, the respective temperature is displayed.
The agitator starts after reaching a standard temperature.
When the agitator runs, you should refill material, if necessary. When the cover is opened the agita-
tor stops immediately. A recurrent signal reminds you of locking the cover again.
When the maximum temperature (T1) is reached, the display turns to T1. Now, the unit maintains the
temperature for 3 minutes to melt the last pieces as well. Do not refill material in this phase. Then,
the cooling down phase starts. The display changes, the ventilator starts and the agitator runs. Now,
the unit cools the material down to 1 degree Celsius below the selected standby temperature T2.
Now, the display changes to T2. The unit regulates the given standby temperature with an accura-
cy of +/- 1 °C (33.8 °F) (when the cup is almost empty, the temperature can temporarily rise by +/-2
°C (35.6 °F). Then, the ventilator starts immediately.)
The program run can only be stopped by turning off the main switch.
Summary: turn the unit on – fill the unit – press T1 – the rest is done automatically.
Ending the program: turn off the power switch (at the back of the unit).