4 Operation
4.1 Before putting into operation
The unit is produced according to the latest technologies and according to the recognized safety
regulations. However, the possibility of dangerous situations cannot be excluded!
- Only use the unit in immaculate condition and in accordance with the operating instructions!
- Observe the recognized regulations for work safety!
- Usage only by qualified personnel!
- Check the unit for technically immaculate condition!
4.2 Initial operation and adjustment of the temperature unit
Connect the unit to the enclosed power cord and to a protective
grounded socket. The main switch is located on the back of the unit
(next to the plug). The pre-setting for the units for the European Union is
“C” and for the units for the USA “F”. After turning the main switch you
have 4 seconds to select a temperature unit.
For a display in degree Celsius press the button “DOWN” (arrow down),
the letter “C” will be displayed.
For a display in degrees Fahrenheit press the button “UP” (arrow up), the letter “F” will be displayed.
After 4 seconds you will hear a short signal and the unit is in standby mode. After this, you cannot
change the temperature unit anymore. The selected temperature unit will remain saved even after
turning the unit off.
Note concerning the Fahrenheit display: Internally, the unit always calculates with degrees Celsius
and then transforms the numbers using the following formula: “°C x 1.8 + 32” . The results are deci-
mal numbers which cannot be displayed and will be rounded either up or down.
Example:
50 °C = 122.0 °F -- Display: 122
51 °C = 123.8 °F -- Display: 124
Therefore the value 123 will never be displayed!
4.3 Filling the device
Open the cover of the unit and skim condensation water (if any) at the cup seal. If some conden-
sation water leaves the unit housing, please remove it with a trap (paper cloth). The split between
the cup and the housing is liquid proof.
Depending on the application there are different methods for filling the unit:
1.
Empty unit: Handling the cover is very easy. Pull the cover a little bit to the front using the handle
until it disengages. Then, lift the cover slightly and turn it to the side. Lifting the cover is very im-
portant because, otherwise, you might strip off the seal! Finally, turn the cover back again until the
angle, press the cover a little bit down (vertically) using the handle and re-engage it. A well-
maintained and slightly greased seal facilitates the procedure. Open the cover and fill the roughly
crushed duplicating material into the unit. The smaller the pieces are, the more you can fill in.
Please do not fill through the agitator because, otherwise, the cover might be lifted and material
could escape.