5.8 Updating the ITX2’s Firmware
From time to time, firmware updates may be available for the ITX2. Effigis provides these
updates via its website. Please visit the Downloads page to obtain the latest firmware release.
To check which version is currently installed in the ITX2, access the setup mode by pressing
the left or right arrow and scroll to the Version menu.
Firmware updates can be automatically performed through the ARD4. To proceed manually,
using an ITX2 linked to a computer through the USB cable, contact the CPAT support team.
6. Maintenance
6.1 Cleaning
Your ITX2 unit can be wiped clean with a damp cloth. Do not immerse the unit in water. Avoid
solvents and commercial cleaners.
6.2 Preventative Maintenance
The technician shall do periodic visual inspections of the ITX2 to make sure that there is
nothing loose or broken. Both can affect the performance of the system. In case that a
replacement is required, please contact Effigis for more information.
Appendix A - Specifications
A.1 Technical
Transmitter modulation
DBPSK
Frequency range
6.78 MHz, 27.12 MHz or 40.68 MHz, set at factory
Bandwidth
30 kHz
Occupied Bandwidth
20 kHz
Antenna connector
BNC 50 Ω
Transmitted data
68 bits
Transmission duration
8 ms
Transmission interval
100 ms
Communication port
USB type A