Photovoltaic Solar Inverter Series ES
Status Diagnosis and Troubleshooting
ES series
67
LCD
display
Description
Explanation
Troubleshooting
Er10
PV inverter
over temperature
The indoor temperature is
too high.
9. Try to reduce the
surrounding
temperature.
10. Install the photovoltaic
solar inverter in a cooler
place.
11. If the error occurs again,
please contact your
dealer.
Er18
Heat sink
over temperature
The temperature on the
cooling element is too
high.
Er01
Ground fault
The fault current has
reached the authorised
upper limit.
12. Disconnect the feed from
the PV generator and
check the peripheral AC
system.
13. When the reason is
found, reconnect the PV
panel and check the
status of the photovoltaic
solar inverter.
14. If the error occurs again,
please contact your
dealer.
Er17
EEPROM
ERROR on the
control board
EEPROM data is faulty.
15. Please contact your
dealer.