Photovoltaic Solar Inverter Series ES
Electrical Installation
ES series
31
5.
Electrical Installation
There is risk of receiving a life-threatening electric shock if you touch live
components.
Only authorised electricians may work on electrical components or
equipment in accordance with electrotechnical rules.
2 Safety Instructions
1
String A
2
String B
3
Data transfer
4
AC output
Fig. 5 - 1 Wiring of the photovoltaic solar inverter
(Example ES4200 / ES5000)
Two strings can be connected with the ES4200 / ES5000 models. Here it
should be ensured that the load on both strings is symmetrical.
This means: One input on the photovoltaic solar inverter can process
50 % of the rated power and may be overloaded by a maximum of 10 %.