![effeff 720-30 Operating And Installation Instructions Download Page 85](http://html1.mh-extra.com/html/effeff/720-30/720-30_operating-and-installation-instructions_2367060085.webp)
85
2.13 Specifications
Power supply
230 V +6%, -10%, 50 - 60 Hz
Maximum current consumption with rated voltage
0.3 A
Input voltage range with external power supply
24 V DC stab15%, -10%
(safety extra-low voltage)
Intrinsic current consumption of the control system
150 mA
Current consumption of the safety relay circuit in 720-32
110 mA
Rated operating voltage
24 V DC
Maximum admissible overall current consumption of all external consumers
appr. 1.1 A
Emergency power supply / battery capacity
24 V DC, 2Ah
Bridging time at rated load:
appr. 15 mins.
Protective measures according to VDE 0100:
Safety class I
Protection rating to DIN EN 60529 2000-09
IP 20
Operating temperature range
0°C to +40°C
Storage temperature range
-20°C to +60°C
Dimensions WxHxD mm
300 x 186 x 125
Colour
RAL 9002 grey-white
Weight (excluding batteries)
720-30:
5.28 kg
720-32:
5.52 kg
Weight of batteries (2 batteries 18002)
1.92 kg