4 / Typical Setup
Caution:
Always depressurize the reservoir
before opening. To do this, slide the shutoff valve
on the air line away from the reservoir. If using
an EFD tank, open the pressure relief valve as
well. Before opening the reservoir, check the
pressure gauge to verify that pressure is zero (0).
On all EFD cartridge reservoirs, the unique
threaded design provides fail-safe air pressure
release during cap removal.
Typical Setup
#7543BP
for 1/4" OD tube
#7610BP
for 3/8" OD tube
LVLP
spray valve
Plant air
70 psi (4.8 bar)
minimum
Material
Constant air
Pulsed air for valve operation
Pulsed nozzle air
VALVEMATE
7040
20
0
5
Note: Use only oil-free,
clean, dry, filtered air
Flexible air line
#2310S
Black quick-connect
Five
micron filter regulator
Air tee #1116
Shut-off valve
White quick-connect
Fluid feed hose
Controller
ValveMate
7040 Controller
Pressurized
reservoir with
air regulator
To exhaust
To pressurize
Fluid inlet
fitting