EFD ValveMate 7040 Operating Manual Download Page 14

Micro-

controller

Opto

coupler

Fuse

Voltage Initiate Circuit

5 to 24 VDC power source 
power consumption
2.2mA at 5 VDC
15.0mA at 24 VDC

End-of-Cycle
Feedback Circuit

5 to 24 VDC power 
source maximum 
load 250mA

1

00/120/220 VAC

50/60 Hz 14/12 VA

+ 5 VDC

Solenoid 1

7815 

control

Protector

Solenoid 2

atomizer

control

Power

 supply

Nonvolatile

memory

Programmable

display

Opto

coupler

+ 24 VDC

Mechanical Contact Initiate

Mechanical contact power 
consumption contact load
 = 5.5 VDC / 100uA

Foot Pedal

+

+

_

_

2

3

4

5

7

1

A relay is 
illustrated 
as one example 
for utilizing the 
feedback circuit.

NOTE:  DO NOT APPLY 
VOLTAGE across pins
5 and 7.

12 / Input / Output Connections

Input/Output Connections

Summary of Contents for ValveMate 7040

Page 1: ...VALVEMATE 7040 Electronic pdf files of EFD manuals are also available at www efd inc com manuals html ValveMate 7040 Controller Operating Manual A NORDSON COMPANY...

Page 2: ...y exceed the purchase price of the equipment This warranty is valid only when oil free clean dry filtered air is used EFD makes no warranty of merchantability or fitness for a particular purpose In no...

Page 3: ...ions 2 Operating Features 3 Typical Setup 4 Setup 5 6 Adjusting the Spray 7 Programming Nozzle Air Delay 8 Schematic and Replacement Parts 9 Troubleshooting Guide 10 Input Output Connections 11 12 Con...

Page 4: ...kg 3 1 lb Cabinet Aluminum Input Voltage Selectable 100 120 220 VAC Internal Voltage 24 VDC Feedback Circuits 5 to 24 VDC NC solid state switch 250mA maximum Initiate Circuit 5 to 24 VDC signal or con...

Page 5: ...999 to 9 99 or 99 9 Decimal does not appear in the display while in the 999 second range Operating Features 4 Program Press to clear display to zeros Display flashes bright dim while in program mode P...

Page 6: ...es fail safe air pressure release during cap removal Typical Setup 7543BP for 1 4 OD tube 7610BP for 3 8 OD tube LVLP spray valve Plant air 70 psi 4 8 bar minimum Material Constant air Pulsed air for...

Page 7: ...00PMK Input Power 1 View cartridge window in power cord receptacle to ensure that the voltage is set properly Selections are 100 120 or 220 VAC 2 If it does not match remove the fuse cartridge Then re...

Page 8: ...ng The quick connect on the air tee is used to provide air pressure to the air pressure regulator on EFD tank reser voirs This connection will be made during valve installation 3 Remove the cap plug f...

Page 9: ...ntrol knob and or tank air pressure Note Avoid tight stroke settings with high tank pressure 4 To change nozzle air use the nozzle air pressure regulator Higher pressures will provide finer spray To M...

Page 10: ...power switch on 3 The display will read SEL select Release the time override button 4 Press either the up or down time set buttons once and release The current nozzle air delay setting will be display...

Page 11: ...ly 7 2001A Gauge 0 to 30 psi 0 to 2 07 bar 8 2004B Female quick connect black hidden from view below item 9 9 2004B W Female quick connect white 10 2024 160 1 4 OD x 160 ID tubing 11 2081A Air input q...

Page 12: ...input voltage Ensure that the external voltage to the circuit is between 5 and 24 VDC and that the load does not exceed 250mA If the circuit has been overloaded the fuse may have blown Replace fuse i...

Page 13: ...le an open collector circuit closes and remains closed until the next dispense cycle This circuit can be utilized to signal back to a host computer start another device in sequence or other operations...

Page 14: ...12 VA 5 VDC Solenoid 1 7815 control Protector Solenoid 2 atomizer control Power supply Nonvolatile memory Programmable display Opto coupler 24 VDC Mechanical Contact Initiate Mechanical contact power...

Page 15: ...h each controller that is connected The initiate power supply should be sized accordingly 2 End of Cycle Feedback Circuit This circuit will ensure that the end of cycle signal will come from the last...