3 / Operating Features
1. Cycle
Press to initiate one complete
dispense cycle. Press again to
interrupt a timed cycle. Press
and hold while in the time over-
ride mode for continuous cycle.
Release to stop.
2. Time override
Press to override time control.
Display will show (---). While in this
mode, dispensing is manual using
the cycle button, voltage initiate
source or foot pedal (optional,
#2015A).
3. Decimal
Press to move decimal and change
time range maximums from .999
to 9.99 or 99.9. Decimal does not
appear in the display while in the
.999 second range.
Operating Features
4. Program
Press to clear display to zeros.
Display flashes bright/dim while in
program mode.
Press cycle button and hold until
proper amount is sprayed. Total
spray time will be displayed. Press
program button again to lock in
spray time.
5. Time set
Press to change time setting up or
down. Press and release to advance
one digit at a time, or press and
hold to scroll quickly.
6. Foot pedal connector
If using the optional foot pedal, press
the pedal momentarily to initiate the
controller. To interrupt a timed dis-
pense cycle, press the pedal again.