Schmid & Wezel
D-75433 Maulbronn
Seite/ Page
19/ 34
Ausführung/ Version
0
2
.20
1
4
3. Remove the hex. nut using the single-head
wrench supplied - turn in anti-clockwise direc-
tion (arrow B). (see Fig. 3)
Figure 3: Loosening the saw blade
4. Replace the saw blade. Place the new saw blade
onto the square drive (see Fig. 4).
Figure 4: Fitting the saw blade
5. Insert the retention pin as a twist lock into the
saw blade bore and the bore below (A)
6. Tighten the hex. nut securely - turn in clockwise
direction (arrow B) and tighten to approx. 50
Figure 5: Fixing the saw blade
7. Remove single-head wrench and retention pin.
8.
EFA SK23/ 18
: Install the depth stop as
described in chapter 3.3.1 "EFA SK23/ 18:" (p.
9. Connect the saw to the works mains again.
10.Carry out a test run.
3.2 Sharpening the saw blade
We have set up a sharpening service in our Service
department. Incorrectly resharpened saw blades
detract from your productivity and also constitute
considerable risks for the user.
An overview of our product range for saw blades
can be seen in Figure 6: Saw blades and Table 2:
Figure 6: Saw blades
6-8 mm
12-20 mm
C
Coarse toothing
40-45 mm
D
Low-noise
toothing
E
Hard metal
toothing
A
Medium-fine toothing
B
Medium-coarse toothing