Mobile animal stunning device VBE-M
13
Switching between modes takes place automatically after connecting the power system to the
mains or disconnecting it.
Operation in battery mode:
1. Turn on the power system using the
ON / OFF
switch located on the housing (
Fig. 5 pos. 1
);
2. After about 10 seconds, turn on the
VBE-M
using the
START
button (
Fig. 6 pos. 1
) - the
device will automatically enter the
readiness for operation mode
;
3.
Fig. 5 pos. 3
- mains supply light is off;
4.
Fig. 5 pos. 4
- battery charging light is off;
5.
Fig. 5 pos. 2
- voltmeter shows the battery charge level.
CAUTION!
If during stunning in battery mode the battery charge level drops below green (
Fig. 5
pos. 2
), it means that the battery is discharged to more than 50%. Then you should stop
stunning and connect the device to the mains in order to charge the battery. During the
stunning process, the battery voltage will drop.
Battery charging:
After connecting the device to the mains, the process of charging the power system battery begins.
The process takes place in 3 stages:
CAUTION!
Do not discharge the battery below 50% as this may damage it.
If the battery is 100% charged, about 100 stunning processes can be carried out (with 2A
current for 20s) - the actual number of stunning processes depends on the set stunning parameters
and may differ from the estimated one.
Fig. 5 Power system - battery mode
Fig. 6 VBE-M
Stage 1
- battery charging with 10A
direct current;
Stage 2
- battery charging with
constant voltage of 14.5V (14.3V -
14.7V);
Stage 3
- recharging the battery in
the range of 500-900 mA.
Diagram 4 Battery charging