Mobile animal stunning device VBE-M
11
7.3 Description of parameters tP1, tP2 and tP3 - stunning modes
Stunning modes
tP1
,
tP2
and
tP3
define how the stunning process takes place in the individual
stunning phases (
dL1
,
dL2
,
dL3
).
Possible variants of setting parameters
tP1
,
tP2
and
tP3
:
●
0 -
head, sinusoidal waveform
;
●
1 -
head, rectangular waveform
;
●
4 -
head-heart
,
sinusoidal waveform
, continuation of stunning after the
transition phase
;
●
5 -
head-heart
,
rectangular waveform
, continuation of stunning after the
transition phase
;
●
12 -
head-heart
,
sinusoidal waveform
, suspension of stunning after the
transition phase
;
●
13 -
head-heart
,
rectangular waveform
, suspension of stunning after the
transition phase
.
The other values of the parameters
tP1
,
tP2
and
tP3
(2, 3, 6, 7, 8, 9, 10, 11) are inactive.
The rectangular waveform allows for stunning with higher current but the frequency is limited to 250
Hz.
Stunning modes:
●
continuous mode
-
head
:
Diagram 1 Current intensity diagram - continuous stunning
-
for each phase (
dL1
,
dL2
,
dL3
) parameters
tP1
,
tP2
and
tP3
should be set to
0
or
1
;
●
two-stage mode
-
head-heart
:
Diagram 2 Current intensity diagram - stunning with continuation in the transition phase