Table 6 Description of the controller parameters that can be reprogrammed
SP1E [A] - end current of stunning phase 1. The current changes fluently from SP1b to SP1E over
the duration of dL1
tP1 -
stunning mode 1
- determines the stunning mode in phase 1 (dL1) - detailed description:
section
7.3
dL2 [s] -
phase 2
- duration of stunning phase 2. Setting dL2 to
0
cancels this phase. The following
parameters will then disappear from the menu: Fr2b; Fr2E; SP2b; SP2E; tP2
Fr2b [Hz] - initial frequency of stunning phase 2. The frequency jumps from Fr1E
Fr2E [Hz] - end frequency of stunning phase 2. The frequency changes from Fr2b to Fr2E over the
duration of dL2
SP2b [A] - initial current of stunning phase 2. The current jumps from SP1E
SP2E [A] - end current of stunning phase 2. The current changes fluently from SP2b to SP2E over
the duration of dL2
tP2 -
stunning mode 2
- determines the stunning mode in phase 2 (dL2) - detailed description:
section
7.3
dL3 [s] -
phase 3
- duration of stunning phase 3. Setting dL3 to
0
cancels this phase. The following
parameters will then disappear from the menu: Fr3b; Fr3E; SP3b; SP3E; tP3
Fr3b [Hz] - initial frequency of stunning phase 3. The frequency jumps from Fr2E. If dL2=0, the
frequency jumps from Fr1E
Fr3E [Hz] - end frequency of stunning phase 3. The frequency changes from Fr3b to Fr3E over the
duration of dL3
SP3b [A] - initial current of stunning phase 3. The current jumps from SP2E. If dL2=0, the current
jumps from SP1E
SP3E [A] - end current of stunning phase 3. The current changes fluently from SP3b to SP3E over
the duration of dL3
tP3 -
stunning mode 3
- determines the stunning mode in phase 3 (dL3) - detailed description:
section
7.3
SPt [s] - duration counted from the beginning of the stunning process. After reaching the set value,
the end of the stunning process will be signalled (the yellow light and the sound alarm turn on) - it
means that the electrodes should be removed from the animal's body
EnHV – activation of selected stunning program :
●
0
- inactive ;
●
1
- active - measuring voltage on electrodes (stunning process starts automatically after
pressing electrodes to the animal's body );
●
2
- does not apply to VBE-M;
●
3