Figure 20 nES750 Dimensions
A. Inlet port
B. Exhaust port
C. Oil level switch
D. Motor connection
E. External filtration connection
A. Inlet port
B. Exhaust port
C. Oil level switch
D. Motor connection
E. External filtration connection
4.2 Installation guidelines
▪
Use the list as a guide for the installation of the vacuum pump. The list is not
exhaustive. Every vacuum pump installation is unique, and care must be used in
the placement of each pump. If you are not sure of any installation variable,
contact us.
▪
For bare-shaft nES pumps supplied without a motor, the installation of a three-
phase electric motor is mandatory before use. Follow the installation procedure
provided with the pump. Bare-shaft pumps are delivered either with an IEC or a
NEMA motor coupling element. Use a motor with the power and frame size that
matches the following specification:
Pump
size
NEMA motor
frame size
NEMA motor
power 60 Hz
IEC motor frame size
(as per IEC60072-1)
IEC motor power
50 Hz/60 Hz
nES40
145TC
2 HP
n/a
n/a
nES65
145TC
3 HP
100 L (B34/FT130)
2.2/3.0 kW
nES100
184TCH
5 HP
100 L (B14/FT130)
3.0/3.6 kW
nES200
213TC
7.5 HP
n/a
n/a
nES300
215TC
10 HP
132 S (B14/FT165)
5.5/6.6 kW
Page 28 - 07/2020