A4.1
Start-up
Refer to
. Before you start the pump, check the following additional points:
z
Check the pressure regulator for the dry nitrogen supply to the gas-ballast solenoid and shaft-seals is set to
4 psi.
z
Check the pressure regulator for the dry nitrogen supply to the oil-box is set to 7 psi.
Figure A3 - Typical dry nitrogen gas circuit
2
3
1
5
8
9
10
11
12
7
6
4
AA/5013/A
1. Filtered dry nitrogen supply (~50 psi)
2. Pressure regulator (set 4 psi)
3. Pressure regulator (set 7 psi)
4. Pressure gauge (0-30 psi)
5. Flow regulator valve
6. Flow meter
7. Dry nitrogen gas to oil-box
8. Main shaft-seals
9. Solenoid valve
10. Non-return valve
11. Fixed restrictor
12. Dry nitrogen gas-ballast input
Summary of Contents for E1M40