Installation
Figure 6 - Electrical supply connection, three-phase motors, 380-415 V 50 Hz, or 460 V 60 Hz
We recommend that you connect the electrical supply to the motor through a starter or circuit breaker which has
thermal over-current protection which can be adjusted to suit the full-load current ratings shown in
. The
fuse ratings in
are provided for guidance only. The supplier of your thermal over-current protection device
may specify different values to ensure correct operation of the over-current protection device. Ensure that the fuse
you use is suitable for the starting currents given in
1. Remove the cover from the motor terminal box.
2. Check your electrical supply voltage and frequency. If necessary, configure the motor to operate with your
electrical supply (see Figures
).
3. Remove the 20 mm diameter plugs from the cable-entry hole that you will use for the electrical supply cable.
Choose the most suitable hole for your application.
4. Fit a suitable cable-gland and nut to the entry hole. After the supply cable is fitted, the cable-gland must be a
protective seal to the standard of IP44 in IEC 529 or better.
5. Pass the motor electrical supply cable through the cable-gland.
6. Connect the cables o the terminals as shown in Figures
and
L1
L2
L3
3
U1
W2
U2
V2
V1
W1
W2
AA/5006/A