Technical data
2.4
Cooling-water supply
2.5
Mechanical data
2.6
Lubrication data
Maximum pressure rise (between HV8000 pump inlet and outlet)
190 mbar
120 mbar
1.9 x 10
3
Pa
1.2 x 10
3
Pa
2.75 psi
1.74 psi
Maximum motor power for a directly (bell housing) mounted motor
18.5 kW
18.5 kW
25 hp
25 hp
Maximum inlet gas temperature
60 °C
60 °C
140 °F
140 °F
Maximum outlet gas temperature
300 °C
300 °C
572 °F
572 °F
Maximum gas temperature rise (between HV8000 inlet and outlet)
240 °C
240 °C
464 °F
464 °F
*
On a pump used with DoL (Direct On Line) starting, this is the critical backing pressure at which the pump
must be shut down (see
). This is not applicable to pumps operated with inverters (See
).
Table 3 - Cooling-water supply data
Maximum supply pressure
3 bar gauge, 3 x 10
5
Pa, 44 psi
Maximum supply temperature
35 °C, 95 °F
Minimum cooling-water flow rate
15 l min
-1
, 3.96 US gal min
-1
Table 4 - Mechanical data
Dimensions
See
Mass
Bareshaft
With 50 Hz motor
With 60 Hz motor
HV8000VF
570 kg, 1257 lb
670 kg, 1474 lb
664 kg, 1460 lb
HV8000HF
570 kg, 1257 lb
670 kg, 1474 lb
664 kg, 1460 lb
Table 5 - Lubrication data
Recommended oil
Mobil SHC 629
Oil capacities
Shaft-seals oil reservoir
Drive end cover
Non-drive end cover
HV8000VF
0.2 litres, 0.05 US gal
3.5 litres, 0.92 US gal
4.6 litres, 1.21 US gal
HV8000HF
0.2 litres, 0.05 US gal
2.0 litres, 0.63 US gal
2.3 litres, 0.61 US gal
Table 2 - Performance data: safe area HV8000 pumps (continued)
HV8000 (50 Hz)
HV8000 (60 Hz)