Page 7
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
A311-03-880 Issue A
2
Technical data
2.1
Operating and storage conditions
Note:
For operation between -20 °C and 5 °C (-4 and 41 °F), we recommend that the HV8000 pump is operated
continuously except when shut-down is necessary for maintenance purposes. Note also the cooling-water
requirements given in
There is a wide range of backing pumps which are suitable for use with the HV8000 pumps. If necessary,
contact Edwards for advice.
2.2
Critical backing pressure
2.3
Performance
Table 1 - Operating and storage conditions
Ambient operating temperature range
-20 to 40 °C, -4 to 104 °F
Ambient storage temperature range
-20 to 80 °C, -4 to 176 °F
Maximum ambient operating humidity
90%
Maximum operating altitude
3000 m, 9842 ft
Protection degree (as defined by IEC 529)
IP44
Recommended backing pumps
See Note above
WARNING
If you fit an isolation valve between the HV8000 pump and the backing pump, you must interlock
the operation of the valve with the operation of the HV8000 pump, so that closure of the valve
results in shut-down of the HV8000 pump.
Table 2 - Performance data: safe area HV8000 pumps
HV8000 (50 Hz)
HV8000 (60 Hz)
Maximum rotational speed
3000 r min
-1
3600 r min
-1
3000 r.p.m.
3600 r.p.m.
Minimum rotational speed (for correct pump lubrication)
440 r min
-1
440 r min
-1
440 r.p.m.
440 r.p.m.
Displacement (swept volume)
7200 m
3
h
-1
8640 m
3
h
-1
4241 cfm
5089 cfm
Maximum backing pressure for DoL (direct on line) starting
6 mbar
7 mbar
6 x 10
2
Pa
7 x 10
2
Pa
0.087 psi
0.1 psi
Minimum backing pumping speed at the pump outlet
400 m
3
h
-1
600 m
3
h
-1
236 cfm
353 cfm
Critical backing pressure at the pump outlet
*
68 mbar
67 mbar
6.8 x 10
3
Pa
6.7 x 10
3
Pa
0.99 psi
0.97 psi