Description
Typical display
Dry pump speed in Hz
DP SPEED
100 Hz
Booster speed in percent
MB SPEED
100 %
Booster speed in Hz
MB SPEED
100 Hz
Dry pump inverter temperature
DP INV TEMP
100 C
Booster inverter temperature
MB INV TEMP
100 C
Exhaust pressure
EXHAUST
5 PSI
Exhaust temperature
EXH PIPE TEMP
100 C
Water flow rate
WATER
11.1 l/m
Run hours
RUN HOURS
1000
Number of pump starts
PUMP STARTS
100
Time to stop (seconds)
TIME TO STOP
900
Active alarms and warnings
Solvent soak
SOLVENTSOAK
Off
Dry pump clean
DP CLEAN
Off
Active strain gauge
ASG
3.4E+01 mbar
PT100 temperature
PT100 1
108 C
Pressure transducer
PR
105.0 kPa
PID auto tune status
PID TUNE
Normal
9.4.3 Setup menu
Press the SETUP button to enter. The menu title is shown at the top of the display. Scroll
by pressing the UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to exit back
to Normal menu.
Table 31
PDT setup menu structure
Description
Display
Commands menu*
Command Menu...
Set sequences menu*
Set Sequences...
Display inverter fault history menu
Inv Fault Hist...
Software version display menu
S/W Version...
Display serial number
Serial Num...
Fit accessory menu*
Fit Accessory...
Edit IP configuration menu
IP Config...
Edit display attributes menu
Display Attr...
Set time and date
Set Clock...
Display pump type
Show pump type...
* This option requires a security code to access it.
Each sub menu is described below.
Page 123
M58800880_H - Pump display terminal
Summary of Contents for 9773512584
Page 6: ...This page has been intentionally left blank ...
Page 87: ...Figure 19 GXS160 installation drawing Sheet 4 Page 83 M58800880_H Installation drawings ...
Page 178: ...This page has been intentionally left blank ...
Page 179: ...This page has been intentionally left blank ...
Page 180: ...edwardsvacuum com ...